{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGR222", "description": "Roller Shutter 2", "devices": [ { "productType": "0x0300", "productId": "0x0102", "zwaveAllianceId": 38 }, { "productType": "0x0301", "productId": "0x1001" }, { "productType": "0x0302", "productId": "0x1000" }, { "productType": "0x0302", "productId": "0x3000" }, { "productType": "0x0302", "productId": "0x4000" } ], "firmwareVersion": { "min": "24.24", "max": "255.255" }, "associations": { "1": { "label": "Momentary click", "maxNodes": 16 }, "2": { "label": "Momentary hold", "maxNodes": 16 }, "3": { "label": "Controller Updates", "maxNodes": 1, "isLifeline": true } }, "proprietary": { "fibaroCCs": [38 /* 0x26 (Venetian Blinds) */] }, "paramInformation": [ { "#": "3", "label": "Reports Type", "description": "value should be set to 1 if the module operates in Venetian Blind mode.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Blind position using Z-Wave command", "value": 0 }, { "label": "Blind position via Fibaro command", "value": 1 } ] }, { "#": "10", "label": "Roller Shutter Operating Modes", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Roller blind mode, without positioning", "value": 0 }, { "label": "Roller blind mode, with positioning", "value": 1 }, { "label": "Venetian blind mode, with positioning", "value": 2 }, { "label": "Gate mode, without positioning", "value": 3 }, { "label": "Gate mode, with positioning", "value": 4 } ] }, { "#": "12", "label": "Turning Time/ Delay Time", "description": "depending on mode, turning time or delay time", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 150, "unsigned": true }, { "#": "13", "label": "Lamellas Positioning Mode", "description": "Parameter influences the lamellas positioning in venetian blind mode", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Only in case of the main controller operation", "value": 0 }, { "label": "Default - Controller+switchlimit", "value": 1 }, { "label": "Like 1 + stop control frame", "value": 2 } ] }, { "#": "14", "label": "Switch Type", "description": "either Toggle switches or a single, momentary switch.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Momentary switches", "value": 0 }, { "label": "Toggle switches", "value": 1 }, { "label": "Single, momentary switch", "value": 2 } ] }, { "#": "17", "label": "Delay Time After S2", "description": "delay till auto turned off or auto gate close", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true }, { "#": "18", "label": "Motor Operation Detection", "description": "Power threshold to be interpreted as reaching a limit switch.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 10, "unsigned": true }, { "#": "22", "label": "Motor Operation Time", "description": "Time period for the motor to continue operation.", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 10, "unsigned": true }, { "#": "29", "label": "Forced Roller Shutter Calibration", "description": "set to 1 will enter calibration mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Deactivated", "value": 0 }, { "label": "Start calibration process", "value": 1 } ] }, { "#": "30", "label": "Response to General Alarm", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "31", "label": "Response to Water Flood Alarm", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "32", "label": "Response to Smoke, CO, CO2 Alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "33", "label": "Response to Temperature Alarm", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "No response to alarm frames", "value": 0 }, { "label": "Open blind", "value": 1 }, { "label": "Close blind", "value": 2 } ] }, { "#": "35", "label": "Managing Lamellas in Response to Alarm", "description": "0 no change, 1 extreme position", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Do not change lamellas position", "value": 0 }, { "label": "Set lamellas to their extreme position", "value": 1 } ] }, { "#": "40", "label": "Power Reports", "description": "change that needs to occur to trigger the power report", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 10 }, { "#": "42", "label": "Periodic Power or Energy Reports", "description": "Time to the next report. Value of 0 means the reports are turned off.", "valueSize": 2, "minValue": 0, "maxValue": 65534, "defaultValue": 3600, "unsigned": true }, { "#": "43", "label": "Energy Reports", "description": "Energy threshold to trigger report", "valueSize": 1, "minValue": 0, "maxValue": 254, "defaultValue": 10, "unsigned": true }, { "#": "44", "label": "Self-Measurement", "description": "if power and energy reports are to sent to the main controller", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Activated", "value": 1 } ] }, { "#": "50", "label": "Scenes/ Associations Activation", "description": "whether scenes or associations are activated by the switch keys", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Associations active", "value": 0 }, { "label": "Scenes active", "value": 1 } ] } ] }