{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGFS101", "description": "Flood Sensor", "devices": [ { "productType": "0x0b00", "productId": "0x1001" }, { "productType": "0x0b01", "productId": "0x1002" }, { "productType": "0x0b01", "productId": "0x1003" }, { "productType": "0x0b00", "productId": "0x2001" }, { "productType": "0x0b01", "productId": "0x2002" }, { "productType": "0x0b01", "productId": "0x2003" }, { "productType": "0x0b00", "productId": "0x3001" }, { "productType": "0x0b01", "productId": "0x3002" }, { "productType": "0x0b01", "productId": "0x3003" }, { "productType": "0x0b00", "productId": "0x4001" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Flood Alarm", "maxNodes": 5 }, "2": { "label": "Tilt & Tamper Sensors", "maxNodes": 5 }, "3": { "label": "Device Status", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Alarm Cancellation Delay", "description": "Time alarm still indicated after alarm condition has ceased", "valueSize": 2, "minValue": 0, "maxValue": 3600, "defaultValue": 0 }, { "#": "2", "$if": "firmwareVersion >= 3.1", "label": "Select Alarm Type (Visual/acoustic)", "description": "This parameter allows for deactivation visual and acoustic alarm.", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Acoustic and visual alarms inactive", "value": 0 }, { "label": "Acoustic alarm inactive, visual alarm active", "value": 1 }, { "label": "Acoustic alarm active, visual alarm inactive", "value": 2 }, { "label": "Acoustic and visual alarms active", "value": 3 } ] }, { "#": "5", "label": "Type Alarm Frame Sent to 1st Assoc Group", "description": "Type of cmd frame sent in case of flooding", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Alarm water", "value": 0 }, { "label": "Basic Set", "value": 255 } ] }, { "#": "7", "label": "Forced Level of Dimming Group 1", "description": "Parameter specifying forced level of dimming f. asoc grp 1", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "9", "label": "Device Off and Alarm Cancellations", "description": "Enable/disable device off/alarm cancellation updates to 2nd/3rd assoc groups", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Alarm (Flooding) cancellation inactive", "value": 0 }, { "label": "Alarm (Flooding) cancellation active", "value": 1 } ] }, { "#": "10", "$if": "firmwareVersion <= 3.1", "label": "Interval Betw. Successive Readings of Temp Sensors", "valueSize": 2, "minValue": 1, "maxValue": 32767, "defaultValue": 300 }, { "#": "10", "$if": "firmwareVersion >= 3.2", "label": "Temperature Measurement Interval", "description": "Seconds between consecutive measurements of battery level/temperature", "valueSize": 4, "minValue": 1, "maxValue": 65535, "defaultValue": 300 }, { "#": "12", "$if": "firmwareVersion <= 3.1", "label": "Temperature Change Report Threshold", "valueSize": 2, "minValue": 0, "maxValue": 1000, "defaultValue": 50 }, { "#": "12", "$if": "firmwareVersion >= 3.2", "label": "Temperature Measurement Hysteresis", "description": "Minimum change in temperature value for report to be sent to controller", "valueSize": 2, "minValue": 1, "maxValue": 1000, "defaultValue": 50 }, { "#": "13", "label": "Alarm BROADCAST", "description": "Transmit the alarm or control frame in 'broadcast' mode", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Broadcast inactive", "value": 0 }, { "label": "Flood broadcast active, tamper broadcast inactive", "value": 1 }, { "label": "Flood broadcast inactive, tamper broadcast active", "value": 2 }, { "label": "Flood and tamper broadcast mode active", "value": 3 } ] }, { "#": "50", "label": "Low Temperature Alarm Threshold", "description": "Temperature value below which LED indicator blinks", "valueSize": 2, "minValue": -10000, "maxValue": 10000, "defaultValue": 1500 }, { "#": "51", "label": "High Temperature Alarm Threshold", "description": "Temperature value above which LED indicator blinks", "valueSize": 2, "minValue": -10000, "maxValue": 10000, "defaultValue": 3500 }, { "#": "61", "label": "Low Temperature Alarm Indicator Colour", "description": "Default is blue (0x000000FF).", "valueSize": 4, "minValue": 0, "maxValue": 16777215, "defaultValue": 255 }, { "#": "62", "label": "High Temperature Alarm Indicator Colour", "description": "Default is red (0x00FF0000). 65535 * Red + 256 * Green + Blue", "valueSize": 4, "minValue": 0, "maxValue": 16777215, "defaultValue": 16711680 }, { "#": "63", "label": "Visual Temperature Indicator", "description": "Enable or disable visual temperature indicator via device's LED", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "No temperature indication", "value": 0 }, { "label": "Every measurement (Battery)", "value": 1 }, { "label": "Every measurement (Power mode)", "value": 2 } ] }, { "#": "73", "label": "Temperature Measurement Compensation", "description": "Temperature value to compensate between air temp", "valueSize": 2, "minValue": -10000, "maxValue": 10000, "defaultValue": 0 }, { "#": "74", "label": "Alarm Frame for Movement/tamper", "description": "Movement/tamper alarm sent to 1st & 4th assoc. group", "valueSize": 1, "defaultValue": 2, "allowManualEntry": false, "options": [ { "label": "Tamper alarm inactive", "value": 0 }, { "label": "Button tamper alarm active", "value": 1 }, { "label": "Movement tamper alarm active", "value": 2 }, { "label": "Button and movement tampers alarm active", "value": 3 } ] }, { "#": "75", "$if": "firmwareVersion <= 3.1", "label": "Visual and Audible Alarms Duration", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "75", "$if": "firmwareVersion >= 3.2", "label": "Alarms Signalization Duration", "description": "Turn off alarm after given timeout", "valueSize": 4, "minValue": 0, "maxValue": 65535, "defaultValue": 0 }, { "#": "76", "$if": "firmwareVersion <= 3.1", "label": "Alarm/basic Retransmission Time When Flooding", "description": "Time period after which alarm frames will be retransmitted", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 0, "unsigned": true }, { "#": "76", "$if": "firmwareVersion >= 3.2", "label": "Alarm Signalization Reactivation Period", "description": "Time period after which an alarm will be turned back on", "valueSize": 4, "minValue": 0, "maxValue": 65535, "defaultValue": 0 }, { "#": "77", "label": "Flood Sensor Functionality Turned Off", "description": "Allows the internal flood sensor to be turned off.", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Flood sensor on", "value": 0 }, { "label": "Built-In flood sensor turned off", "value": 1 } ] }, { "#": "78", "$if": "firmwareVersion >= 3.2", "label": "Associations in Z-Wave Network Security Mode", "description": "Defines whether commands are sent as secure or non-secure", "valueSize": 1, "defaultValue": 7, "allowManualEntry": false, "options": [ { "label": "None of the groups are sent as secure", "value": 0 }, { "label": "2nd group ”Control” sent as secure", "value": 1 }, { "label": "3rd group ”Alarm” sent as secure", "value": 2 }, { "label": "4th group ”Tamper” sent as secure", "value": 3 } ] } ] }