{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGDW002", "description": "Fibaro Door Window Sensor 2", "devices": [ { "productType": "0x0702", "productId": "0x1000" }, { "productType": "0x0702", "productId": "0x2000" }, { "productType": "0x0702", "productId": "0x3000" }, { "productType": "0x0702", "productId": "0x4000" }, { "productType": "0x0702", "productId": "0x7000" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Door/window State", "description": "What state is door/window when the magnet is close to the sensor", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Closed when magnet near", "value": 0 }, { "label": "Opened when magnet near", "value": 1 } ] }, { "#": "3", "label": "Associations in Z-Wave Network Security Mode", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "None of the groups sent as secure", "value": 0 }, { "label": "2nd group \"On/off\" sent as secure", "value": 1 }, { "label": "3rd group \"Tamper\" sent as secure", "value": 2 }, { "label": "2nd and 3rd group sent as secure", "value": 3 } ] }, { "#": "11", "label": "2nd Association Group Triggers", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Switch after opening and closing", "value": 0 }, { "label": "Switch after opening (Parameter 12)", "value": 1 }, { "label": "Switch after closing (Parameter 13)", "value": 2 } ] }, { "#": "12", "label": "Value of ON Command Sent to 2nd Association Group", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "13", "label": "Value of OFF Command Sent to 2nd Association Group", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "14", "label": "Association for Opening - Time Delay", "valueSize": 2, "minValue": 0, "maxValue": 32400, "defaultValue": 0 }, { "#": "15", "label": "Association for Closing - Time Delay", "valueSize": 2, "minValue": 0, "maxValue": 32400, "defaultValue": 0 }, { "#": "30", "label": "Tamper - Alarm Cancellation Delay", "valueSize": 2, "minValue": 0, "maxValue": 32400, "defaultValue": 5 }, { "#": "31", "label": "Tamper - Reporting Alarm Cancellation", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Do not send tamper cancellation report", "value": 0 }, { "label": "Send tamper cancellation report", "value": 1 } ] }, { "#": "50", "label": "Interval of Temperature Measurements", "valueSize": 2, "minValue": 0, "maxValue": 32400, "defaultValue": 300 }, { "#": "51", "label": "Temperature Reports Threshold", "valueSize": 2, "minValue": 0, "maxValue": 300, "defaultValue": 10 }, { "#": "52", "label": "Interval of Temperature Reports", "valueSize": 2, "minValue": 0, "maxValue": 32400, "defaultValue": 0 }, { "#": "53", "label": "Temperature Offset", "valueSize": 2, "minValue": -1000, "maxValue": 1000, "defaultValue": 0 }, { "#": "54", "label": "Temperature Alarm Reports", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Temperature alarms disabled", "value": 0 }, { "label": "High temperature alarm", "value": 1 }, { "label": "Low temperature alarm", "value": 2 }, { "label": "High and low temperature alarms enabled", "value": 3 } ] }, { "#": "55", "label": "High Temperature Alarm Threshold", "valueSize": 2, "minValue": 1, "maxValue": 600, "defaultValue": 350 }, { "#": "56", "label": "Low Temperature Alarm Threshold", "valueSize": 2, "minValue": 0, "maxValue": 599, "defaultValue": 100 }, { "#": "2[0x01]", "label": "Visual LED Indications - Open/close", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "No indication", "value": 0 }, { "label": "Open/Close indication", "value": 1 } ] }, { "#": "2[0x02]", "label": "Visual LED Indications - Wake Up", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "No indication", "value": 0 }, { "label": "Enable wake up notification", "value": 1 } ] }, { "#": "2[0x04]", "label": "Visual LED Indications - Tampering", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "No indication", "value": 0 }, { "label": "Enable indication of device tampering", "value": 1 } ] } ] }