{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGD211", "description": "Universal Dimmer 500W", "devices": [ { "productType": "0x0100", "productId": "0x0100", "zwaveAllianceId": 88 }, { "productType": "0x0100", "productId": "0x0104" }, { "productType": "0x0100", "productId": "0x0106" }, { "productType": "0x0100", "productId": "0x0107" }, { "productType": "0x0100", "productId": "0x0109" }, { "productType": "0x0100", "productId": "0x100a" }, { "productType": "0x0100", "productId": "0x300a" }, { "productType": "0x0100", "productId": "0x400a" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Switch 1", "maxNodes": 5 }, "2": { "label": "Switch 2", "maxNodes": 5 }, "3": { "label": "Controller Updates", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Enable/Disable ALL ON/OFF", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "All on active / All off active", "value": 255 }, { "label": "All on disabled / All off disabled", "value": 0 }, { "label": "All on disabled / All off active", "value": 1 }, { "label": "All on active / All off disabled", "value": 2 } ] }, { "#": "6", "label": "Send Commands to Association Group 1", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Send on/off commands", "value": 0 }, { "label": "Send off; Turn on at last brightness", "value": 1 }, { "label": "Send off; Turn on at 100%", "value": 2 } ] }, { "#": "7", "label": "Control Key #2 Behaviour", "description": "Key no. 2 is not represented by any physical device", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Device status is not checked", "value": 0 }, { "label": "Device status is checked", "value": 1 } ] }, { "#": "8", "label": "Dimming Step At Automatic Control", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "9", "label": "Transition Time Between Values", "description": "Options for changing parameter 1-255 (10ms - 2,5s)", "valueSize": 1, "minValue": 1, "maxValue": 255, "defaultValue": 5, "unsigned": true }, { "#": "10", "label": "Time of AUTOMATIC Moving Between Values", "description": "Time of autom. moving the dimmer between min/max", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 1, "unsigned": true }, { "#": "11", "label": "Dimming Step At Manual Control", "description": "Options for changing parameter 1-99", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 1 }, { "#": "12", "$if": "firmwareVersion <= 2.0", "label": "Maximum Dimmer Level Control", "description": "Options for changing parameter 2-99", "valueSize": 1, "minValue": 2, "maxValue": 99, "defaultValue": 2 }, { "#": "12", "$if": "firmwareVersion >= 2.1", "label": "Maximum Dimmer Level Control", "description": "Options for changing parameter 2-99", "valueSize": 1, "minValue": 2, "maxValue": 99, "defaultValue": 99 }, { "#": "13", "$if": "firmwareVersion <= 2.0", "label": "Minimum Dimmer Level Control", "description": "Options for changing parameter 1-98", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true }, { "#": "13", "$if": "firmwareVersion >= 2.1", "label": "Minimum Dimmer Level Control", "description": "Options for changing parameter 1-98", "valueSize": 1, "minValue": 1, "maxValue": 98, "defaultValue": 2 }, { "#": "14", "$if": "firmwareVersion <= 2.1", "label": "Inputs Button/Switch Configuration", "description": "Binary inputs type configuration", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Monostable input (Button)", "value": 0 }, { "label": "Bistable input (Switch)", "value": 1 } ] }, { "#": "14", "$if": "firmwareVersion >= 2.2", "label": "Inputs Button/Switch Configuration", "description": "Binary inputs type configuration", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Monostable input (Button)", "value": 0 }, { "label": "Bistable input (Switch)", "value": 1 }, { "label": "Roller blind switch", "value": 2 } ] }, { "#": "15", "$if": "firmwareVersion <= 2.0", "label": "Parm 15", "description": "Double-click set lighting at 100%", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disable double click", "value": 0 }, { "label": "Enable double click", "value": 1 } ] }, { "#": "15", "$if": "firmwareVersion >= 2.1", "label": "Parm 15", "description": "Double-click set lighting at 100%", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Disable double click", "value": 0 }, { "label": "Enable double click", "value": 1 } ] }, { "#": "16", "$import": "~/templates/master_template.json#state_after_power_failure_off_prev" }, { "#": "17", "label": "3-Way Switch", "description": "Function of 3-way switch", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "18", "label": "Synchronizing Light Level for Associated Devices", "description": "The dimmer communicate the level to the associated devices. (default value 0)", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "19", "label": "Change [On-Off] Bistable Keys", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Device changes status on key status change", "value": 0 }, { "label": "Device status depends on key status", "value": 1 } ] }, { "#": "20", "label": "Control Impulse Length", "valueSize": 1, "minValue": 100, "maxValue": 170, "defaultValue": 110, "unsigned": true }, { "#": "30", "label": "Relay 1: Response to General Alarm", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Deactivation - No response to alarm frames", "value": 0 }, { "label": "Alarm relay on", "value": 1 }, { "label": "Alarm relay off", "value": 2 }, { "label": "Alarm flashing", "value": 3 } ] }, { "#": "39", "label": "ALARM FLASHING Alarm Time", "description": "Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame", "valueSize": 2, "minValue": 0, "maxValue": 65535, "defaultValue": 600, "unsigned": true }, { "#": "40", "$if": "firmwareVersion >= 1.9 && firmwareVersion <= 2.0", "label": "Updating the Dimming Level without Switch", "description": "Parameter’s value changes depending on the dimming level.", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 99, "unsigned": true }, { "#": "40", "$if": "firmwareVersion >= 2.1", "label": "Updating the Dimming Level without Switch", "description": "Available settings: from 1 to 99.", "valueSize": 1, "minValue": 1, "maxValue": 99, "defaultValue": 99 }, { "#": "41", "$if": "firmwareVersion >= 1.9", "label": "Scene Activation Functionality", "description": "Command class scene activation for group no. 3", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Scene functionality deactivated", "value": 0 }, { "label": "Scene functionality activated", "value": 1 } ] } ] }