{ "manufacturer": "Fibargroup", "manufacturerId": "0x010f", "label": "FGCD001", "description": "Carbon Monoxide Sensor", "devices": [ { "productType": "0x1201", "productId": "0x1000" }, { "productType": "0x1201", "productId": "0x1001" }, { "productType": "0x1201", "productId": "0x1002" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "2", "label": "Z-Wave Notifications", "description": "Set the actions sent to controller", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Both actions disabled", "value": 0 }, { "label": "Tampering (Opened casing)", "value": 1 }, { "label": "Exceeding the temperature", "value": 2 }, { "label": "Both actions enabled", "value": 3 } ] }, { "#": "3", "label": "LED Diode Indications", "description": "Set the actions which result in LED diode indications", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "All actions disabled", "value": 0 }, { "label": "Tampering (Opened casing)", "value": 1 }, { "label": "Exceeding the temperature", "value": 2 }, { "label": "Tampering and exceeding the temperature", "value": 3 }, { "label": "Lack of Z-Wave range", "value": 4 }, { "label": "Tampering (Opened casing) and lack of Z-Wave range", "value": 5 }, { "label": "Exceeding the temperature and lack of Z-Wave range", "value": 6 }, { "label": "Tampering and exceeding the temp and lack of range", "value": 7 } ] }, { "#": "4", "label": "Acoustic Signals", "description": "Set the actions which result in acoustic signals", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "All actions disabled", "value": 0 }, { "label": "Tampering (Opened casing)", "value": 1 }, { "label": "Exceeding the temperature", "value": 2 }, { "label": "Tampering and exceeding the temperature", "value": 3 }, { "label": "Lack of Z-Wave range", "value": 4 }, { "label": "Tampering and lack of Z-Wave range", "value": 5 }, { "label": "Exceeding the temperature and lack of Z-Wave range", "value": 6 }, { "label": "Tampering and exceeding temp and lack of range", "value": 7 } ] }, { "#": "7", "label": "Associations in Z-Wave Network Security Mode", "description": "Secure or non-secure commands to assoc groups", "valueSize": 1, "minValue": 0, "maxValue": 63, "defaultValue": 63 }, { "#": "10", "label": "Commands Sent to 2nd Association Group (CO Alarm)", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Basic Set (On)", "value": 1 }, { "label": "Basic Set (Off)", "value": 2 }, { "label": "Basic Set (On & off)", "value": 3 } ] }, { "#": "11", "label": "Value of BASIC ON Command Sent to 2nd Assoc Group", "valueSize": 2, "defaultValue": 255, "allowManualEntry": false, "options": [ { "label": "Turning associated devices off", "value": 0 }, { "label": "Forcing level of associated devices", "value": 1 }, { "label": "Setting assoc device to last value or on", "value": 255 } ] }, { "#": "12", "label": "Value of BASIC OFF Cmd Sent to 2nd Assoc Group", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0 }, { "#": "13", "label": "Commands Sent to 4th Association Group (CO Level)", "description": "Defines cmd sent to devices in 4th association group", "valueSize": 1, "minValue": 1, "maxValue": 3, "defaultValue": 3, "readOnly": true }, { "#": "14", "label": "CO Level for Sending BASIC ON to 4th Assoc Group", "description": "Defines min level of CO concentration starting timer", "valueSize": 2, "minValue": 25, "maxValue": 400, "defaultValue": 40 }, { "#": "15", "label": "Time Required for BASIC ON Cmd to 4th Assoc Group", "description": "Defines time of CO concentration should remain above param values", "valueSize": 2, "minValue": 0, "maxValue": 2880, "defaultValue": 0 }, { "#": "16", "label": "Value of BASIC ON Cmd Sent to 4th Assoc Group", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255 }, { "#": "17", "label": "CO Level for Sending BASIC OFF to 4th Assoc Group", "valueSize": 2, "minValue": 10, "maxValue": 400, "defaultValue": 25 }, { "#": "19", "label": "Value of BASIC OFF Cmd Sent to 4th Assoc Group", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 0, "readOnly": true }, { "#": "20", "label": "Temperature Reporting Time Interval", "description": "Time interval between consecutive reports of temperature", "valueSize": 2, "minValue": 0, "maxValue": 1440, "defaultValue": 0 }, { "#": "21", "label": "Temperature Reporting Hysteresis", "description": "Min change in temperature resulting in a report being sent", "valueSize": 1, "minValue": 1, "maxValue": 20, "defaultValue": 2 }, { "#": "22", "label": "Threshold of Exceeding the Temperature", "description": "Temp level resulting in sending actions (parameters 2, 3 and 4)", "valueSize": 1, "minValue": 1, "maxValue": 85, "defaultValue": 55 }, { "#": "23", "label": "CO Meter Activation", "description": "Activates reporting of CO concentration to controller.", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1 }, { "#": "25", "label": "CO Level Reporting Hysteresis", "description": "Minchange in CO concentration resulting in sending new value to controller", "valueSize": 1, "minValue": 2, "maxValue": 6, "defaultValue": 2 }, { "#": "26", "label": "Threshold of CO Meter Activation", "description": "Defines CO concentration level sending a new value to controller", "valueSize": 2, "minValue": 10, "maxValue": 255, "defaultValue": 30 } ] }