{ "manufacturer": "Team Precision PCL", "manufacturerId": "0x0089", "label": "ZSL301EU", "description": "Single Relay Switch", "devices": [ { "productType": "0x0001", "productId": "0x0101" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "0", "$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off" }, { "#": "1", "label": "Night Light", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "LED on when light on", "value": 0 }, { "label": "LED on when light off", "value": 1 } ] }, { "#": "2", "$import": "~/templates/master_template.json#base_enable_disable", "label": "LED Indicator", "defaultValue": 1 }, { "#": "3", "label": "Enable All ON/All OFF", "valueSize": 1, "defaultValue": 255, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Enable both all on and all off command", "value": 255 }, { "label": "Disable both all on and all off command", "value": 0 }, { "label": "Enable only all off command", "value": 1 }, { "label": "Enable only all on command", "value": 2 } ] }, { "#": "4", "label": "Button Protection", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "User can use button for on/off manual control", "value": 0 }, { "label": "Protect mode", "value": 1 }, { "label": "Disable button from manual control", "value": 2 } ] }, { "#": "5", // eslint-disable-next-line @zwave-js/consistent-config-string-case "label": "Delay In Time", "valueSize": 1, "unit": "seconds", "minValue": 0, "maxValue": 5, "defaultValue": 0 }, { "#": "6", "label": "Delay Out Time", "valueSize": 1, "unit": "seconds", "minValue": 0, "maxValue": 5, "defaultValue": 0 } ] }