{ "manufacturer": "FortrezZ LLC", "manufacturerId": "0x0084", "label": "MIMOlite", "description": "Digital or Analog Voltage Input And/or Dry Contact Relay", "devices": [ { "productType": "0x0451", "productId": "0x010e" }, { "productType": "0x0451", "productId": "0x0110" }, { "productType": "0x0453", "productId": "0x010e" }, { "productType": "0x0453", "productId": "0x010f" }, { "productType": "0x0453", "productId": "0x0110" }, { "productType": "0x0453", "productId": "0x0111", "zwaveAllianceId": 1756 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Binary input Set Group", "maxNodes": 2 }, "2": { "label": "MultiLevel Sensor report", "maxNodes": 2, "isLifeline": true }, "3": { "label": "Power Alarm", "maxNodes": 2, "isLifeline": true }, "4": { "label": "Binary Sensor report", "maxNodes": 2, "isLifeline": true }, "5": { "label": "Pulse Meter Sensor report", "maxNodes": 2 } }, "paramInformation": [ { "#": "2", "label": "Clear_Pulse_Meter_Counts", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Clear pulse meter counts", "value": 0 } ] }, { "#": "3", "label": "Trigger_Mapping", "description": "Input-to-relay Mapping", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "SIG1 triggered/untriggered sets or clears Relay1", "value": 1 } ] }, { "#": "4", "label": "Lower_Threshold_High", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 187, "unsigned": true, "options": [ { "label": "Default (0xBB)", "value": 187 } ] }, { "#": "5", "label": "Lower_Threshold_Low", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 171, "unsigned": true, "options": [ { "label": "Default (0xAB)", "value": 171 } ] }, { "#": "6", "label": "Upper_Threshold_High", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true, "options": [ { "label": "Default (0xFF)", "value": 255 } ] }, { "#": "7", "label": "Upper_Threshold_Low", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 254, "unsigned": true, "options": [ { "label": "Default (0xFE)", "value": 254 } ] }, { "#": "8", "label": "Trigger_Level_And_Input_Threshold", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Analog, trigger outside of thresholds", "value": 0 }, { "label": "Analog, trigger between thresholds", "value": 1 }, { "label": "Digital, trigger outside of thresholds", "value": 2 }, { "label": "Digital, trigger between thresholds", "value": 3 } ] }, { "#": "9", "label": "Multilevel_AutoReport_Interval", "valueSize": 1, "defaultValue": 3, "allowManualEntry": false, "options": [ { "label": "Disable automatic reports", "value": 0 }, { "label": "Enable reports every 30 seconds", "value": 3 } ] }, { "#": "11", "label": "Momentary_Relay1_Duration", "description": "Momentary Relay1 output enable/disable (100msec).", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true, "options": [ { "label": "Disabled", "value": 0 }, { "label": "500 milliseconds", "value": 5 } ] } ] }