{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "ST815", "description": "Illumination Sensor", "devices": [ { "productType": "0x0007", "productId": "0x0001", "zwaveAllianceId": [2, 210, 975] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Reports", "maxNodes": 1, "isLifeline": true }, "2": { "label": "Control", "maxNodes": 3 } }, "paramInformation": [ { "#": "1", "label": "Dim Level Sent via Basic Set", "description": "The dim level sent to a lamp module upon activation: (0) Off; (1)-(99) Dim Level", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 99 }, { "#": "2", "label": "Lux Trigger On Value", "valueSize": 2, "minValue": 0, "maxValue": 1000, "defaultValue": 300 }, { "#": "3", "label": "Lux Trigger Off Value", "valueSize": 2, "minValue": 0, "maxValue": 1000, "defaultValue": 500 }, { "#": "4", "label": "Lux Trigger Off Timer Value", "valueSize": 2, "minValue": 0, "maxValue": 480, "defaultValue": 0 }, { "#": "5", "label": "Auto Report Time Interval", "valueSize": 2, "minValue": 0, "maxValue": 1439, "defaultValue": 0 }, { "#": "6", "label": "Auto Report Lux Interval", "valueSize": 2, "minValue": 0, "maxValue": 1000, "defaultValue": 0 } ] }