{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "HSP02 / SP103", "description": "Motion Detector", "devices": [ { "productType": "0x0001", "productId": "0x0001", "zwaveAllianceId": [24, 35, 392] }, { "productType": "0x0001", "productId": "0x0003", "zwaveAllianceId": [926, 976] }, { "productType": "0x0101", "productId": "0x0001", "zwaveAllianceId": 873 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Target for reports", "maxNodes": 1, "isLifeline": true }, "2": { "label": "Target nodes who receive BASIC_SET command", "maxNodes": 5 } }, "paramInformation": [ { "#": "1", "label": "Basic Set Level", "description": "Value to be sent with a BASIC SET command", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 99 }, { "#": "2", "label": "Sensor Detecting Function", "valueSize": 1, "defaultValue": 1, "allowManualEntry": false, "options": [ { "label": "Group 1 enabled / Group 2 enabled", "value": 1 }, { "label": "Group 1 enabled / Group 2 disabled", "value": 2 }, { "label": "Group 1 disabled / Group 2 disabled", "value": 3 } ] }, { "#": "3", "label": "Sensitivity Level", "valueSize": 1, "minValue": 1, "maxValue": 10, "defaultValue": 6 }, { "#": "4", "label": "Re-Trigger Interval Setting", "valueSize": 1, "minValue": 5, "maxValue": 255, "defaultValue": 180, "unsigned": true }, { "#": "5", "label": "LUX Level", "description": "Value for what LUX level will arm the detection sensor", "valueSize": 1, "minValue": 1, "maxValue": 100, "defaultValue": 10 }, { "#": "6", "label": "On-Off Duration", "valueSize": 1, "minValue": 5, "maxValue": 255, "defaultValue": 15, "unsigned": true } ], "compat": { // The device is a Binary Sensor, but uses Basic Sets to report its status "mapBasicSet": "auto" } }