{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "HAC01", "description": "In-Wall Remote Insert", "devices": [ { "productType": "0x0010", "productId": "0x0001", "zwaveAllianceId": 694 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Switch Input Change", "description": "Target nodes that receive Basic Set command when the switch input changed.", "maxNodes": 5, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Basic Set Level", "description": "The Basic Set Command is sent with this value.", "valueSize": 1, "minValue": 0, "maxValue": 99, "defaultValue": 99 }, { "#": "2", "label": "Amount of Delay", "description": "Amount Of Delay (seconds) to send the Basic Set Off command.", "valueSize": 1, "unit": "seconds", "minValue": 0, "maxValue": 127, "defaultValue": 1 } ], "compat": { "mapBasicSet": "auto", // The device supports Binary Switch CC, despite the Version query telling otherwise "commandClasses": { "add": { "Binary Switch": { "isSupported": true, "version": 1 } } } } }