{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "EH403", "description": "Z-Wave Floodlight with Motion Detector", "devices": [ { "productType": "0x0012", "productId": "0x0001", "zwaveAllianceId": 2890 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "PIR Trigger Off Period", "description": "Pir trigger off period can be set 8~720 secs", "valueSize": 2, "minValue": 8, "maxValue": 720, "defaultValue": 15 }, { "#": "2", "label": "Lux Sensor Threshold", "description": "Lux sensor threshold can be set 30~200", "valueSize": 2, "minValue": 30, "maxValue": 200, "defaultValue": 50, "writeOnly": true }, { "#": "3", "label": "Lux Auto Report", "description": "Lux auto report can be set 0~1440 minutes", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 1440, "defaultValue": 0 } ], "metadata": { "inclusion": "Auto Inclusion\nThe unit supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset.\n\n1. Prepare the Z-Wave controller.\n2. Plug the cable plug to the wall socket to power up the unit.\n3. The Link LED will start to blink slowly with 2-second on, 2-second off (for 2 minutes) which shows the unit does not be paired.\n4. Within 30 seconds, put the Z-Wave Controller into inclusion mode.\n5. The Inclusion process should be completed when the Link LED stops blinking.\n\nNote: If you are connecting this unit to a Z-Wave Controller that utilizes the S2 security protocol, you may be asked by your controller to enter a 5-digit Device Specific Key (DSK) that is unique to each unit. This can be found in one of two places:\n- on the QR code label on the back of the unit\n- on the insert card inside the packaging.\n\n6. Turn on the floodlight using the controller to check if the auto inclusion is working properly.\n\nManual Inclusion\n1. Prepare the Z-Wave controller.\n2. Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode", "exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode", "reset": "1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode\n2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds).\n3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.\n4. Please use this procedure only when the network primary controller is missing or otherwise inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2890/EH403%20Manual_20180522修改-A501112670R.pdf" }, "compat": { "commandClasses": { "remove": { // The device does not support Supervision correctly "Supervision": { "endpoints": "*" } } } } }