{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "AN188", "description": "Metering Plug", "devices": [ { "productType": "0x0004", "productId": "0x000d", "zwaveAllianceId": 3139 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "1", "label": "Basic Set Command Value", "description": "Allowable Range: 0-99", "valueSize": 2, "minValue": 0, "maxValue": 255, "defaultValue": 255, "options": [ { "label": "On", "value": 255 } ] }, { "#": "2", "label": "Group 1: Report Delay", "description": "Delaying time to report to group 1", "valueSize": 1, "unit": "seconds", "minValue": 3, "maxValue": 25, "defaultValue": 3 }, { "#": "3", "label": "Restore State After Power Loss", "valueSize": 1, "minValue": 0, "maxValue": 1, "defaultValue": 1, "options": [ { "label": "Disable", "value": 0 }, { "label": "Enable", "value": 1 } ] }, { "#": "4", "label": "Wattage Report Interval", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 32767, "defaultValue": 1 }, { "#": "5", "label": "kWh Report Interval", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 32767, "defaultValue": 60 }, { "#": "6", "label": "Wattage Report Threshold", "valueSize": 2, "unit": "W", "minValue": 0, "maxValue": 3500, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] }, { "#": "7", "label": "Wattage Report Relative Change Threshold", "valueSize": 1, "minValue": 0, "maxValue": 100, "defaultValue": 0, "options": [ { "label": "Disable", "value": 0 } ] } ], "metadata": { "inclusion": "1. Put the Z-Wave Controller into inclusion mode.\n2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode.", "exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.", "reset": "1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.\n2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds).\n3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 25 secs.\n(Use this procedure only in the event that the network primary controller is missing, or otherwise inoperable.)", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3139/AN188.pdf" } }