{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "AN163", "description": "Metering Power Switch", "devices": [ { "productType": "0x0004", "productId": "0x0005", "zwaveAllianceId": 979 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Grouping 1", "description": "Grouping 1 reports status", "maxNodes": 1, "isLifeline": true }, "2": { "label": "Grouping 2", "description": "Allows control of up to four other devices", "maxNodes": 4 } }, "paramInformation": [ { "#": "1", "label": "True Period", "description": "Timeout before unit transmits ON/OFF state after manual button press", "valueSize": 1, "unit": "100ms", "minValue": 0, "maxValue": 120, "defaultValue": 10 }, { "#": "2", "label": "Send Basic Command to Group 2", "description": "Configure the unit to send command to other devices in Grouping 2", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Disabled", "value": 0 }, { "label": "Enabled", "value": 1 } ] }, { "#": "3", "label": "Meter Report Period (W)", "description": "How often the meter should report load (W).", "valueSize": 2, "unit": "10s", "minValue": 0, "maxValue": 3240, "defaultValue": 3 }, { "#": "4", "label": "Meter Report Period (kWh)", "description": "How often the meter should report load (kWh).", "valueSize": 2, "unit": "minutes", "minValue": 0, "maxValue": 10080, "defaultValue": 1440 } ] }