{ "manufacturer": "Everspring", "manufacturerId": "0x0060", "label": "AC301", "description": "Thermostatic Radiator Valve", "devices": [ { "productType": "0x0015", "productId": "0x0001", "zwaveAllianceId": 4641 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "maxNodes": 1, "isLifeline": true } }, "paramInformation": [ { "#": "1", "label": "Temperature Auto Report Period Setting", "valueSize": 2, "unit": "minutes", "minValue": 1, "maxValue": 255, "defaultValue": 120 }, { "#": "2", "label": "Temperature Offset for Internal Sensor", "description": "Temperature offset for internal sensor (-80~+80 Offsets the measured temperature by -8.0 °C~+8.0 °C)", "valueSize": 1, "unit": "1/10 °C", "minValue": -80, "maxValue": 80, "defaultValue": 0 }, { "#": "3", "label": "Maximum Set Point Value", "valueSize": 1, "unit": "°C", "minValue": 5, "maxValue": 35, "defaultValue": 35 }, { "#": "4", "label": "Minimum Set Point Value", "valueSize": 1, "unit": "°C", "minValue": 5, "maxValue": 35, "defaultValue": 5 }, { "#": "5", "label": "Frost Protection Temperature", "valueSize": 1, "unit": "°C", "minValue": 5, "maxValue": 15, "defaultValue": 5 }, { "#": "6", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Open Window Detect Function" }, { "#": "7", "label": "Open Window Detect Time Period", "valueSize": 1, "unit": "minutes", "minValue": 2, "maxValue": 30, "defaultValue": 15 }, { "#": "8", "label": "Open Window Detect Temperature Drop Setting", "valueSize": 1, "defaultValue": 4, "allowManualEntry": false, "options": [ { "label": "2 °C", "value": 4 }, { "label": "2.5 °C", "value": 5 }, { "label": "3 °C", "value": 6 }, { "label": "3.5 °C", "value": 7 }, { "label": "4 °C", "value": 8 } ] }, { "#": "9", "label": "Open Window Detect Delay Time Select", "valueSize": 1, "unit": "minutes", "minValue": 10, "maxValue": 60, "defaultValue": 30 }, { "#": "10", "label": "Manual Override Duration", "valueSize": 1, "unit": "30 minutes", "minValue": 1, "maxValue": 48, "defaultValue": 8 } ], "metadata": { "inclusion": "1. Put the Z-Wave Controller into inclusion mode.\n2. Press the P button 3 times within 1.5 seconds to put the unit into inclusion mode.", "exclusion": "1. Put the Z-Wave Controller into exclusion mode.\n2. Press the P button 3 times within 1.5 seconds to put the unit into exclusion mode.", "reset": "1. Press the P button 3 times within 1.5 seconds to put the unit into exclusion mode.\n2. Within 1 second of step 1, press the button P again and hold for 5 seconds.\n3. Node ID is excluded. The device reverts to factory default state.", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/4641/ZRT-106%20user%20manual.pdf" }, "compat": { // This device only accepts Thermostat Setpoint Set commands with a specific float encoding "overrideFloatEncoding": { "precision": 1, "size": 2 }, "commandClasses": { "remove": { // The device does not support Supervision correctly "Supervision": { "endpoints": "*" } } } } }