{ "manufacturer": "Somfy", "manufacturerId": "0x0047", "label": "Z2RTSEU-5", "description": "Z-WAVE2RTS Interface", "devices": [ { "productType": "0x3001", "productId": "0x0b01", "zwaveAllianceId": [1913, 2760] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "metadata": { "inclusion": "Inclusion:\n1. Enable the Z-Wave HUB into the Inclusion mode.\n2. Short press the Z-Wave PROG button for 3 times. ZWave2RTS interface will be included in the Z-Wave network automatically.\n3. The Z-WAVE LED turns OFF indicating that the Z-Wave2RTS interface has successfully joined the Z-Wave network", "exclusion": "Exclusion:\n1. Power ON the Z-Wave2RTS interface.\n2. Enable the Z-Wave HUB into exclusion mode.\n3. Short press the Z-Wave PROG button for 3 times.\n4. The Z-WAVE LED flashes indicating that the Z-Wave2RTS interface has successfully been removed from the Z-Wave network", "reset": "Reset the Z-Wave module to factory mode:\n1. Power OFF the Z-Wave2RTS interface.\n2. Press and hold the Z-Wave PROG button.\n3. Power ON the Z-Wave2RTS interface and wait for 10 seconds.\n4. The Z-Wave LED flashes indicating that the data is cleared and it is open to join Z-Wave network.\n\nRemark: Please use this procedure only in the event that your network primary controller is missing or otherwise inoperable!!!", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2760/Product%20user%20manual%20AU%20version%20v1.1.pdf" } }