{ "manufacturer": "Allegion", "manufacturerId": "0x003b", "label": "BE469", "description": "Touchscreen Deadbolt", "devices": [ { "productType": "0x6341", "productId": "0x5044", "zwaveAllianceId": 748 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Alarm Reports", "maxNodes": 2, "isLifeline": true } }, "paramInformation": [ { "#": "3", "$import": "~/templates/master_template.json#base_enable_disable_255", "label": "Beeper", "defaultValue": 255 }, { "#": "4", "$import": "~/templates/master_template.json#base_enable_disable_255", "label": "Vacation Mode" }, { "#": "5", "$import": "~/templates/master_template.json#base_enable_disable_255", "label": "Lock & Leave" }, { "#": "6", "label": "User Slot Status", "valueSize": 4, "minValue": 0, "maxValue": 255, "defaultValue": 0, "readOnly": true }, { "#": "7", "label": "Lock Specific Alarm Mode", "description": "BE469 Only", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Alarm off", "value": 0 }, { "label": "Alert", "value": 1 }, { "label": "Tamper", "value": 2 }, { "label": "Forced entry", "value": 3 } ] }, { "#": "8", "label": "Lock Specific Alarm Alert Sensitivity", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Not supported", "value": 0 }, { "label": "Most sensitive", "value": 1 }, { "label": "More sensitive", "value": 2 }, { "label": "Medium sensitivity", "value": 3 }, { "label": "Less sensitive", "value": 4 }, { "label": "Least sensitive", "value": 5 } ] }, { "#": "9", "label": "Lock Specific Alarm Tamper Sensitivity", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Not supported", "value": 0 }, { "label": "Most sensitive", "value": 1 }, { "label": "More sensitive", "value": 2 }, { "label": "Medium sensitivity", "value": 3 }, { "label": "Less sensitive", "value": 4 }, { "label": "Least sensitive", "value": 5 } ] }, { "#": "10", "label": "Lock Specific Alarm Kick Sensitivity", "description": "BE469 Only", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "Not supported", "value": 0 }, { "label": "Most sensitive", "value": 1 }, { "label": "More sensitive", "value": 2 }, { "label": "Medium sensitivity", "value": 3 }, { "label": "Less sensitive", "value": 4 }, { "label": "Least sensitive", "value": 5 } ] }, { "#": "11", "label": "Lock Specific Alarm Disable—Local Controls", "valueSize": 1, "defaultValue": 0, "unsigned": true, "allowManualEntry": false, "options": [ { "label": "Disable local control", "value": 0 }, { "label": "Enable local control", "value": 255 } ] }, { "#": "12", "label": "Electronic Transition Count", "valueSize": 4, "minValue": 0, "maxValue": 2147483647, "defaultValue": 0, "readOnly": true }, { "#": "13", "label": "Mechanical Transition Count", "valueSize": 4, "minValue": 0, "maxValue": 2147483647, "defaultValue": 0, "readOnly": true }, { "#": "14", "label": "Electronic Failed Count", "valueSize": 4, "minValue": 0, "maxValue": 2147483647, "defaultValue": 0, "readOnly": true }, { "#": "15", "$import": "~/templates/master_template.json#base_enable_disable_255", "label": "Auto Lock" }, { "#": "16", "label": "User Code PIN Length", "valueSize": 1, "minValue": 4, "maxValue": 8, "defaultValue": 4 }, { "#": "18", "label": "Get Bootloader Version", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 0, "unsigned": true, "readOnly": true } ] }