{ "manufacturer": "Honeywell", "manufacturerId": "0x0039", "label": "39337 / 39444 / ZW4103", "description": "Plug-In 1-Outlet Switch, 500S", "devices": [ { "productType": "0x5052", "productId": "0x3038", "zwaveAllianceId": [2686, 3744] } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "3", "label": "LED Indicator", "valueSize": 1, "defaultValue": 0, "allowManualEntry": false, "options": [ { "label": "LED on when device is off", "value": 0 }, { "label": "LED on when device is on", "value": 1 }, { "label": "Always off", "value": 2 } ] } ], "metadata": { "inclusion": "1. Follow the instructions for your Z-Wave certified controller to include the device to the Z-Wave network. \n2. Once the controller is ready to include your smart switch, single press and release the manual/program button on the smart dimmer to include it in the network.\n3. Once your controller has confirmed that the smart switch has been included, refresh the Z-Wave network to optimize performance.", "exclusion": "1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. \n2. Once the controller is ready to exclude your device, press and release the manual/program button on the smart switch to exclude it from the network.", "reset": "1. If plugged in, unplug the device from the receptacle.\n2. Press and hold the top button, plug the device in, and continue to hold for at least 3 seconds.\nNote: This should only be used in the event your network’s\nprimary controller is missing or otherwise inoperable", "manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2686/39337-HQSG_v1.pdf" } }