{ "manufacturer": "Express Controls", "manufacturerId": "0x001e", "label": "EZMultiPli", "description": "Multi Sensor", "devices": [ { "productType": "0x0004", "productId": "0x0001" } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "associations": { "1": { "label": "Lifeline", "description": "This group is normally automatically assigned to the Z-Wave system controller when EZMultiPli is added to the Z-Wave network.", "maxNodes": 1, "isLifeline": true }, "2": { "label": "Basic", "description": "This group is used to directly turn lights on or off when motion is detected.", "maxNodes": 4 } }, "paramInformation": [ { "#": "1", "label": "OnTime", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 127, "defaultValue": 10 }, { "#": "2", "label": "OnLevel", "description": "Allowable range: 0-99, 255", "valueSize": 1, "minValue": 0, "maxValue": 255, "defaultValue": 255, "unsigned": true }, { "#": "3", "label": "LiteMin", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 127, "defaultValue": 60 }, { "#": "4", "label": "TempMin", "description": "A Temperature report is sent to the controller every TempMin minutes.", "valueSize": 1, "unit": "minutes", "minValue": 0, "maxValue": 127, "defaultValue": 60 }, { "#": "5", "label": "TempAdj", "valueSize": 1, "minValue": -128, "maxValue": 127, "defaultValue": 0 } ] }