{ "manufacturer": "HomeSeer Technologies", "manufacturerId": "0x000c", "label": "HS-LS100+", "description": "Z-Wave Plus Leak Sensor", "devices": [ { "productType": "0x0201", "productId": "0x000a", "zwaveAllianceId": 2735 } ], "firmwareVersion": { "min": "0.0", "max": "255.255" }, "paramInformation": [ { "#": "14", "$import": "templates/homeseer_template.json#enable_basic_set_command" }, { "#": "15", "$import": "templates/homeseer_template.json#basic_set_value" }, { "#": "17", "$import": "~/templates/master_template.json#base_0-255_nounit", "label": "Flood Alarm Interval", "unit": "minutes", "defaultValue": 5 }, { "#": "18", "$import": "templates/homeseer_template.json#enable_shock_alarm" }, { "#": "19", "label": "Temperature Report Interval", "valueSize": 1, "unit": "1/10 minutes", "minValue": 3, "maxValue": 240, "defaultValue": 144, "unsigned": true }, { "#": "20", "label": "Temperature (High) Alarm Trigger Threshold", "valueSize": 2, "unit": "0.1 °F", "minValue": -670, "maxValue": 2570, "defaultValue": 1040 }, { "#": "22", "label": "Temperature (Low) Trigger Threshold", "valueSize": 2, "unit": "0.1 °F", "minValue": -670, "maxValue": 2570, "defaultValue": 320 }, { "#": "24", "$import": "~/templates/master_template.json#base_enable_disable", "label": "Enable / Disable Blinking LED", "defaultValue": 1 }, { "#": "32", "$import": "templates/homeseer_template.json#low_battery_level" } ], "metadata": { "inclusion": "1) Open the cover.\n2) Place the device within the direct range of your Z-Wave controller.\n3) Set the main controller in add mode (see the controller’s manual).\n4) Click the Z-button once (non-secure inclusion) or triple click (secure inclusion) the Z-button quickly, the LED indicator should blink fast. \n5) Wait for the adding process to end.\n6) Successful adding will be confirmed by the Z-Wave controller’s message.", "exclusion": "1) Open the cover.\n2) Place the device within the direct range of your Z-Wave controller.\n3) Set the main controller remove mode (see the controller’s manual).\n4) Triple click the Z-button quickly, the LED indicator should blink fast.\n5) Wait for the removing process to end.\n6) Successful adding will be confirmed by the Z-Wave controller’s message.", "reset": "1) Power on the device\n2) Press and hold the Z button for more than 20 seconds,\n3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete.\n4) The reset feature works only when the device has been included into a Z-Wave network.\n\nUse this procedure only in the event that the network primary controller is missing or otherwise inoperable.", "manual": "https://docs.homeseer.com/products/hs-ls100-user-guide" } }