zwave-js/.config-db/devices/0x5254/zxt-600.json

294 lines
5 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Remotec",
"manufacturerId": "0x5254",
"label": "ZXT-600",
"description": "AC Master",
"devices": [
{
"productType": "0x0100",
"productId": "0x8490"
},
{
"productType": "0x0101",
"productId": "0x8490"
},
{
"productType": "0x0102",
"productId": "0x8490"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "25",
"label": "Learn IR Code",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Off",
"value": 0
},
{
"label": "On (Resume)",
"value": 1
},
{
"label": "17 °C cool",
"value": 2
},
{
"label": "18 °C cool",
"value": 3
},
{
"label": "19 °C cool",
"value": 4
},
{
"label": "20 °C cool",
"value": 5
},
{
"label": "21 °C cool",
"value": 6
},
{
"label": "22 °C cool",
"value": 7
},
{
"label": "23 °C cool",
"value": 8
},
{
"label": "24 °C cool",
"value": 9
},
{
"label": "25 °C cool",
"value": 10
},
{
"label": "26 °C cool",
"value": 11
},
{
"label": "27 °C cool",
"value": 12
},
{
"label": "28 °C cool",
"value": 13
},
{
"label": "29 °C cool",
"value": 14
},
{
"label": "30 °C cool",
"value": 15
},
{
"label": "17 °C heat",
"value": 16
},
{
"label": "18 °C heat",
"value": 17
},
{
"label": "19 °C heat",
"value": 18
},
{
"label": "20 °C heat",
"value": 19
},
{
"label": "21 °C heat",
"value": 20
},
{
"label": "22 °C heat",
"value": 21
},
{
"label": "23 °C heat",
"value": 22
},
{
"label": "24 °C heat",
"value": 23
},
{
"label": "25 °C heat",
"value": 24
},
{
"label": "26 °C heat",
"value": 25
},
{
"label": "27 °C heat",
"value": 26
},
{
"label": "28 °C heat",
"value": 27
},
{
"label": "29 °C heat",
"value": 28
},
{
"label": "30 °C heat",
"value": 29
},
{
"label": "Dry mode",
"value": 30
},
{
"label": "Auto mode",
"value": 31
},
{
"label": "Fan mode",
"value": 32
}
]
},
{
"#": "26",
"label": "IR Code Learning Status",
"valueSize": 1,
"minValue": 0,
"maxValue": 4,
"readOnly": true,
"options": [
{
"label": "Idle - IR channel idle",
"value": 0
},
{
"label": "OK - The last learning operation was completed successfully",
"value": 1
},
{
"label": "Learning - ZXT-600 is busy processing previous learning request",
"value": 2
},
{
"label": "Full all locations are being used",
"value": 3
},
{
"label": "The last learning request was failed",
"value": 4
}
]
},
{
"#": "27",
"label": "IR Code Number From Built-In Code Library",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 1,
"unsigned": true
},
{
"#": "30",
"label": "Auto Report Condition by Room Temp Change",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "0.5 °C",
"value": 1
},
{
"label": "1 °C",
"value": 2
},
{
"label": "1.5 °C",
"value": 3
},
{
"label": "2 °C",
"value": 4
},
{
"label": "2.5 °C",
"value": 5
},
{
"label": "3 °C",
"value": 6
},
{
"label": "3.5 °C",
"value": 7
},
{
"label": "4 °C",
"value": 8
}
]
},
{
"#": "32",
"$import": "~/templates/master_template.json#base_enable_disable_255",
"label": "Built-In IR Emitter Control",
"defaultValue": 255
},
{
"#": "33",
"label": "AC Swing Function",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Swing off",
"value": 0
},
{
"label": "Swing auto",
"value": 1
}
]
},
{
"#": "34",
"label": "Auto Report Time Interval",
"valueSize": 1,
"unit": "hours",
"minValue": 1,
"maxValue": 8,
"defaultValue": 8
},
{
"#": "37",
"label": "Calibrate Temperature Reading",
"valueSize": 1,
"unit": "°C",
"minValue": -5,
"maxValue": 5,
"defaultValue": 0
}
],
"metadata": {
"inclusion": "When it is prompted to enter it, please triple click the PROG button within 1 second. Green Indicator flashes TWICE then stay off.",
"exclusion": "When it is prompted to enter it, please triple click the PROG button within 1 second. Green Indicator flashes TWICE then stay off.",
"reset": "Press and Hold “PROG” button for 3 seconds on AC Master, the Green Indicator will light up. DO NOT Release the “PROG” Button until Green Indicator flashes TWICE."
}
}