zwave-js/.config-db/devices/0x0384/ha-zw-5sab.json

227 lines
5.6 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "AiBase Smart Technology",
"manufacturerId": "0x0384",
"label": "HA-ZW-5SAB",
"description": "4-in-1 Motion Sensor",
"devices": [
{
"productType": "0x0200",
"productId": "0x0009",
"zwaveAllianceId": 2943
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
},
"2": {
"label": "Group 2",
"maxNodes": 5
}
},
"paramInformation": [
{
"#": "10",
"label": "Low Battery Power Level",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 10,
"defaultValue": 10
},
{
"#": "100",
"label": "Set Reporting Intervals to Default",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "101",
"label": "Temperature Reporting Interval",
"valueSize": 4,
"unit": "minutes",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 7200,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "102",
"label": "Humidity Reporting Interval",
"valueSize": 4,
"unit": "minutes",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 7200,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "103",
"label": "Luminance Reporting Interval",
"valueSize": 4,
"unit": "minutes",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 7200,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "104",
"label": "Battery Level Reporting Interval",
"valueSize": 4,
"unit": "minutes",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 86400,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "110",
"label": "Status Change (Temperature/Humidity/Luminance/Battery) Reporting",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Enable",
"value": 1
}
]
},
{
"#": "111",
"label": "Temperature Change Threshold",
"valueSize": 2,
"unit": "0.1 °C",
"minValue": 0,
"maxValue": 10,
"defaultValue": 10
},
{
"#": "112",
"label": "Humidity Change Threshold",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 5,
"defaultValue": 5
},
{
"#": "113",
"label": "Luminance Change Threshold",
"valueSize": 2,
"unit": "lux",
"minValue": 1,
"maxValue": 65528,
"defaultValue": 150,
"unsigned": true
},
{
"#": "114",
"label": "Battery Level Change Threshold",
"valueSize": 1,
"unit": "%",
"minValue": 0,
"maxValue": 10,
"defaultValue": 10
},
{
"#": "12",
"label": "Motion Sensor Sensitivity",
"description": "1 = lowest sensitivity, 10 = highest sensitivity",
"valueSize": 1,
"minValue": 0,
"maxValue": 10,
"defaultValue": 10,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "13",
"label": "Motion Re-Trigger Wait Time",
"valueSize": 2,
"unit": "seconds",
"minValue": 5,
"maxValue": 15300,
"defaultValue": 30
},
{
"#": "14",
"label": "Send Basic Set On Motion",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Enable",
"value": 1
}
]
},
{
"#": "15",
"label": "Motion: Basic Set Value",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "0xff on triggered, 0x00 on cleared",
"value": 0
},
{
"label": "0x00 on triggered, 0xff on cleared",
"value": 1
}
]
}
],
"metadata": {
"inclusion": "Add 4-in-1 Motion Sensor into a Z-Wave network: \na. Let the primary controller go into inclusion mode (If you dont know how to do this, refer to its manual).\nb. Short Press one time this Z-Button.\nc. The 4-in-1 Motion Sensor LED will blink, If the inclusion is successful, then LED will keep on 2 seconds. Otherwise, the LED will blink until timeout, in which case you need to repeat the process from step b.",
"exclusion": "Remove 4-in-1 Motion Sensor from a Z-Wave network: \na. Let the primary controller go into exclusion mode (If you dont know how to do this, refer to its manual).\nb. Short Press one time this Z-Button.\nc. The 4-in-1 Motion Sensor LED will keep on, If the remove is successful, then LED will blink 2 seconds. Otherwise, the LED will keep on until timeout, in which case you need to repeat the process from step b.\n\nNote: 4-in-1 Motion Sensor will go away “Z-Wave SmartStart” Inclusion when it is removed from a Z-Wave network.",
"reset": "Reset 4-in-1 Motion Sensor to factory Default:\n1. Press and hold the Z-Button for 5 seconds.\n2. If holding time is more than 5 seconds, the LED will blink fast at acceleration. If reset success 4-in-1 Motion Sensor LED will turn off. When the Z-Button is released, it will send “Device Reset Locally Command”. Otherwise please repeat step 2.\n\nNote:\n1, This procedure should only be used when the primary controller is inoperable.\n2, Reset 4-in-1 Motion Sensor to factory default settings. It will set the 4-in-1 Motion Sensor to not in Z-Wave network state; delete the Association setting and restore the Configuration setting to the default.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2943/AIBASE%20Z-Wave%20Multi-Sensor%20UserGuide%2020180606.pdf"
}
}