zwave-js/.config-db/devices/0x0234/zif5029.json

224 lines
5.6 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Logic Group",
"manufacturerId": "0x0234",
"label": "ZIF5029",
"description": "DIN Rail Metering",
"devices": [
{
"productType": "0x0003",
"productId": "0x0122"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"$import": "templates/logic_group_template.json#status_led"
},
{
"#": "2",
"$import": "templates/logic_group_template.json#led_brightness"
},
{
"#": "3",
"$import": "templates/logic_group_template.json#output_function_relay",
"label": "Output 1 - Function"
},
{
"#": "4",
"$import": "templates/logic_group_template.json#output_function_relay",
"label": "Output 2 - Function"
},
{
"#": "5",
"$import": "templates/logic_group_template.json#output_function_relay",
"label": "Output 3 - Function"
},
{
"#": "6",
"$import": "templates/logic_group_template.json#output_function_relay",
"label": "Output 4 - Function"
},
{
"#": "7",
"$import": "templates/logic_group_template.json#output_function_relay",
"label": "Output 5 - Function"
},
{
"#": "8",
"$import": "templates/logic_group_template.json#output_function_relay",
"label": "Output 6 - Function"
},
{
"#": "9",
"$import": "templates/logic_group_template.json#meter_type",
"label": "Input 1 - Meter Type"
},
{
"#": "10",
"$import": "templates/logic_group_template.json#input_scale",
"label": "Input 1 - Scale Type"
},
{
"#": "11",
"$import": "templates/logic_group_template.json#input_precision",
"label": "Input 1 - Precision"
},
{
"#": "12",
"$import": "templates/logic_group_template.json#pulse_unit",
"label": "Input 1 - Pulses Per Unit"
},
{
"#": "13",
"$import": "templates/logic_group_template.json#rate_type",
"label": "Input 1 - Rate Type"
},
{
"#": "14",
"$import": "templates/logic_group_template.json#meter_type",
"label": "Input 2 - Meter Type"
},
{
"#": "15",
"$import": "templates/logic_group_template.json#input_scale",
"label": "Input 2 - Scale Type"
},
{
"#": "16",
"$import": "templates/logic_group_template.json#input_precision",
"label": "Input 2 - Precision"
},
{
"#": "17",
"$import": "templates/logic_group_template.json#pulse_unit",
"label": "Input 2 - Pulses Per Unit"
},
{
"#": "18",
"$import": "templates/logic_group_template.json#rate_type",
"label": "Input 2 - Rate Type"
},
{
"#": "19",
"$import": "templates/logic_group_template.json#meter_type",
"label": "Input 3 - Meter Type"
},
{
"#": "20",
"$import": "templates/logic_group_template.json#input_scale",
"label": "Input 3 - Scale Type"
},
{
"#": "21",
"$import": "templates/logic_group_template.json#input_precision",
"label": "Input 3 - Precision"
},
{
"#": "22",
"$import": "templates/logic_group_template.json#pulse_unit",
"label": "Input 3 - Pulses Per Unit"
},
{
"#": "23",
"$import": "templates/logic_group_template.json#rate_type",
"label": "Input 3 - Rate Type"
},
{
"#": "24",
"$import": "templates/logic_group_template.json#meter_type",
"label": "Input 4 - Meter Type"
},
{
"#": "25",
"$import": "templates/logic_group_template.json#input_scale",
"label": "Input 4 - Scale Type"
},
{
"#": "26",
"$import": "templates/logic_group_template.json#input_precision",
"label": "Input 4 - Precision"
},
{
"#": "27",
"$import": "templates/logic_group_template.json#pulse_unit",
"label": "Input 4 - Pulses Per Unit"
},
{
"#": "28",
"$import": "templates/logic_group_template.json#rate_type",
"label": "Input 4 - Rate Type"
},
{
"#": "29",
"$import": "templates/logic_group_template.json#meter_type",
"label": "Input 5 - Meter Type"
},
{
"#": "30",
"$import": "templates/logic_group_template.json#input_scale",
"label": "Input 5 - Scale Type"
},
{
"#": "31",
"$import": "templates/logic_group_template.json#input_precision",
"label": "Input 5 - Precision"
},
{
"#": "32",
"$import": "templates/logic_group_template.json#pulse_unit",
"label": "Input 5 - Pulses Per Unit"
},
{
"#": "33",
"$import": "templates/logic_group_template.json#rate_type",
"label": "Input 5 - Rate Type"
},
{
"#": "34",
"$import": "templates/logic_group_template.json#meter_type",
"label": "Input 6 - Meter Type"
},
{
"#": "35",
"$import": "templates/logic_group_template.json#input_precision",
"label": "Input 6 - Scale Type"
},
{
"#": "36",
"$import": "templates/logic_group_template.json#input_precision",
"label": "Input 6 - Precision"
},
{
"#": "37",
"$import": "templates/logic_group_template.json#pulse_unit",
"label": "Input 6 - Pulses Per Unit"
},
{
"#": "38",
"$import": "templates/logic_group_template.json#rate_type",
"label": "Input 6 - Rate Type"
},
{
"#": "39",
"$import": "templates/logic_group_template.json#time_interval_report",
"label": "Time Interval Between Meter Reports"
}
],
"metadata": {
"inclusion": "Push the button in the hole near the 'INCLUSION' text with a non-conductive object. The LED will now start blinking",
"exclusion": "Push the button in the hole near the 'INCLUSION' text with a non-conductive object. The LED will now start blinking",
"reset": "Push the button in the hole near the 'INCLUSION' text with a non-conductive object for 10 seconds. Please use this procedure only when the network primary controller is missing or otherwise inoperable"
}
}