zwave-js/.config-db/devices/0x019b/tf016_tf021.json

273 lines
6.5 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Heatit",
"manufacturerId": "0x019b",
"label": "TF016 / TF021",
"description": "Z-Wave Thermostat",
"devices": [
{
"productType": "0x0001",
"productId": "0x0001",
// One of these is labeled TF016, the other TF021
"zwaveAllianceId": [1182, 1234]
},
{
"productType": "0x0003",
"productId": "0x0201"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 8,
"isLifeline": true
},
"2": {
"label": "On/Off control",
"maxNodes": 8
}
},
"paramInformation": [
{
"#": "1",
"label": "Operation Mode",
"valueSize": 2,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Off",
"value": 0
},
{
"label": "Heat",
"value": 1
},
{
"label": "Cool",
"value": 2
},
{
"label": "Energy save heat",
"value": 11
}
]
},
{
"#": "2",
"$if": "firmwareVersion >= 1.8",
"label": "Sensor Mode",
"valueSize": 2,
"defaultValue": 1,
"allowManualEntry": false,
/* eslint-disable @zwave-js/consistent-config-string-case */
"options": [
{
"label": "F",
"value": 0
},
{
"label": "A",
"value": 1
},
{
"label": "AF",
"value": 2
},
{
"label": "A2-mode",
"value": 3
},
{
"label": "P",
"value": 4
},
{
"label": "FP",
"value": 5
}
]
/* eslint-enable @zwave-js/consistent-config-string-case */
},
{
"#": "3",
"$if": "firmwareVersion >= 1.8",
"label": "Floor Sensor Type",
"valueSize": 2,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "10k NTC",
"value": 0
},
{
"label": "12k NTC",
"value": 1
},
{
"label": "15k NTC",
"value": 2
},
{
"label": "22k NTC",
"value": 3
},
{
"label": "33k NTC",
"value": 4
},
{
"label": "47k NTC",
"value": 5
}
]
},
{
"#": "4",
"$if": "firmwareVersion >= 1.8",
"label": "DIFF L. Temperature Control Hysteresis",
"description": "Range 3-30 (0.3 °C 3.0 °C)",
"valueSize": 2,
"minValue": 3,
"maxValue": 30,
"defaultValue": 5
},
{
"#": "5",
"$if": "firmwareVersion >= 1.8",
"label": "FLo, Floor Min Limit",
"description": "Range 50-400 (5.0 °C 40.0 °C)",
"valueSize": 2,
"minValue": 50,
"maxValue": 400,
"defaultValue": 50
},
{
"#": "6",
"$if": "firmwareVersion >= 1.8",
"label": "FHi, Floor Max Limit",
"description": "Range 50-400 (5.0 °C 40.0 °C)",
"valueSize": 2,
"minValue": 50,
"maxValue": 400,
"defaultValue": 400
},
{
"#": "7",
"$if": "firmwareVersion >= 1.8",
"label": "ALo, Air Min Limit",
"description": "Range 50-400 (5.0 °C 40.0 °C)",
"valueSize": 2,
"minValue": 50,
"maxValue": 400,
"defaultValue": 50
},
{
"#": "8",
"$if": "firmwareVersion >= 1.8",
"label": "AHi, Air Max Limit",
"description": "Range 50-400 (5.0 °C 40.0 °C)",
"valueSize": 2,
"minValue": 50,
"maxValue": 400,
"defaultValue": 400
},
{
"#": "9",
"$if": "firmwareVersion >= 1.8",
"label": "PLo, FP-Mode P Setting",
"valueSize": 2,
"minValue": 0,
"maxValue": 9,
"defaultValue": 0
},
{
"#": "10",
"$if": "firmwareVersion >= 1.8",
"label": "CO Mode Setpoint",
"description": "Range 50-400 (5.0 °C 40.0 °C)",
"valueSize": 2,
"minValue": 50,
"maxValue": 400,
"defaultValue": 210
},
{
"#": "11",
"$if": "firmwareVersion >= 1.8",
"label": "ECO Mode Setpoint",
"description": "Range 50-400 (5.0 °C 40.0 °C)",
"valueSize": 2,
"minValue": 50,
"maxValue": 400,
"defaultValue": 180
},
{
"#": "12",
"$if": "firmwareVersion >= 1.8",
"label": "P Setting",
"valueSize": 2,
"minValue": 0,
"maxValue": 10,
"defaultValue": 2
},
{
"#": "13",
"$if": "firmwareVersion >= 1.8",
"label": "COOL Setpoint",
"description": "Only if cooling enabled. Range 50-400 (5.0 °C - 40.0 °C)",
"valueSize": 2,
"minValue": 50,
"maxValue": 400,
"defaultValue": 210
},
{
"#": "17",
"$if": "firmwareVersion >= 1.92",
"label": "Temperature Report Interval",
"valueSize": 2,
"unit": "10 seconds",
"minValue": 0,
"maxValue": 8640,
"defaultValue": 6,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "18",
"$if": "firmwareVersion >= 1.92",
"label": "Temperature Report Change Threshold",
"valueSize": 1,
"unit": "0.1 °C",
"minValue": 1,
"maxValue": 100,
"defaultValue": 10
}
],
"compat": {
// The device reports its relay state via the Basic CC
"mapBasicReport": false,
// Supervision reports are sent from the root device instead of endpoints
"commandClasses": {
"remove": {
"Supervision": {
"endpoints": "*"
}
}
}
},
"metadata": {
"inclusion": "To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds.\nThe display will show OFF. Press Right (down) 4 times till you see Con in the display.\nNow start adding the device in your home automation software. Start inclusion mode by pressing Center (confirm) for approximately 2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear.\nLeave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings",
"exclusion": "To exclude the thermostat from your home automation gateway, press Center (confirm) for 10 seconds.\nThe display will show OFF. Press Right (down) 4 times till you see Con in the display.\nNow start removing the device in your home automation software. Enter exclusion mode by pressing Center (confirm) for approximately 2 seconds. The inclusion/exclusion icon will appear in the display. Confirmation will show Inc/EcL in the display. If exclusion fails, Err (error) will appear.\nLeave programming mode by choosing ESC in menu. Your thermostat is ready for use with default settings",
"reset": "By pressing buttons Left and Center (up and confirm) for 20 seconds, the thermostat will perform a complete factory reset.\nPlease use this procedure only when the primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1234/Manual_Multireg%20Z-Wave_Ver2015-A.pdf"
}
}