"manufacturer": "Wink Inc.",
|
|||
|
"manufacturerId": "0x017f",
|
|||
|
"label": "D/W SENSOR",
|
|||
|
"description": "Door/Window Sensor",
|
|||
|
"devices": [
|
|||
|
{
|
|||
|
"productType": "0x0100",
|
|||
|
"productId": "0x0001",
|
|||
|
"zwaveAllianceId": 2494
|
|||
|
}
|
|||
|
],
|
|||
|
"firmwareVersion": {
|
|||
|
"min": "0.0",
|
|||
|
"max": "255.255"
|
|||
|
},
|
|||
|
"paramInformation": [
|
|||
|
{
|
|||
|
"#": "1",
|
|||
|
"label": "Basic Set Off Delay",
|
|||
|
"valueSize": 2,
|
|||
|
"unit": "seconds",
|
|||
|
"minValue": 0,
|
|||
|
"maxValue": 65535,
|
|||
|
"defaultValue": 30,
|
|||
|
"unsigned": true
|
|||
|
},
|
|||
|
{
|
|||
|
"#": "2",
|
|||
|
"label": "Basic Set Level",
|
|||
|
"description": "Allowable range: 0-99, 255",
|
|||
|
"valueSize": 1,
|
|||
|
"minValue": 0,
|
|||
|
"maxValue": 255,
|
|||
|
"defaultValue": 99,
|
|||
|
"unsigned": true,
|
|||
|
"options": [
|
|||
|
{
|
|||
|
"label": "Off",
|
|||
|
"value": 0
|
|||
|
},
|
|||
|
{
|
|||
|
"label": "On",
|
|||
|
"value": 255
|
|||
|
}
|
|||
|
]
|
|||
|
}
|
|||
|
],
|
|||
|
"metadata": {
|
|||
|
"inclusion": "Follow the instructions for your Z-Wave certified Controller to enter inclusion mode.\nWhen prompted by the Controller:\n1. For proper inclusion, bring the Door/Window Sensor within range of your Controller.\n2. Pull the battery tab on the backside of the sensor to power on, or remove then re-install the batteries. The LED light should blink",
|
|||
|
"exclusion": "Follow the instructions for your Z-Wave certified Controller to enter exclusion mode. When prompted by the Controller:\n1. Press the sensor cover release button to remove the top cover, and be sure the sensor is powered on.\n2. Press the Connect Button next to the battery quickly 3 times in a row.\n\nThe LED indicator will flash five times indicating exclusion/disconnection",
|
|||
|
"reset": "If needed, the Door/Window Sensor can be reset locally by following these steps. Only do this when your Z-Wave controller is disconnected or otherwise unreachable. Beware that resetting your device will disconnect it from the system:\n1. Remove the SENSOR COVER and confirm that your Door/Window Sensor is powered up.\n2. Press and hold the BUTTON for at least 10 seconds then release. A flashing light indicates a successful factory reset.\n3. The Door/Window Sensor’s memory will be erased to factory settings",
|
|||
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2494/Wink-Door-Sensor-Manual.pdf"
|
|||
|
}
|
|||
|
}
|