zwave-js/.config-db/devices/0x0175/mt2761.json

249 lines
7.6 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Devolo",
"manufacturerId": "0x0175",
"label": "MT2761",
"description": "Home Control Shutter",
"devices": [
{
"productType": "0x0003",
"productId": "0x0052",
"zwaveAllianceId": 2962
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true,
// The device does not like Endpoint Associations for the lifeline
"multiChannel": false
},
"2": {
"label": "Basic on/off - triggered at change of the input I1 state and reflecting its state.",
"maxNodes": 16
},
"3": {
"label": "Basic on/off - triggered at change of the input I2 state and reflecting its state.",
"maxNodes": 16
},
"4": {
"label": "Basic on/off - triggered at sensing moving direction of roller: up=FF, down=0.",
"maxNodes": 16
},
"5": {
"label": "Basic on/off - triggered at reaching roller position: bottom=FF, top=0.",
"maxNodes": 16
},
"6": {
"label": "Basic on/off - triggered at reaching roller position: bottom=FF, not bottom=0.",
"maxNodes": 16
},
"7": {
"label": "Multilevel set - triggered at changes of value of the Flush Shutter DC position.",
"maxNodes": 16
},
"8": {
"label": "Multilevel set - triggered at changes of value of slats tilting position.",
"maxNodes": 16
},
"9": {
"label": "Multilevel sensor report - triggered at change of temperature sensor.",
"maxNodes": 16,
"isLifeline": true,
// The device does not like Endpoint Associations for the lifeline
"multiChannel": false
}
},
"paramInformation": [
{
"#": "10",
"label": "ALL ON/ALL OFF",
"description": "Responds to commands ALL ON / ALL OFF from Main Controller",
"valueSize": 2,
"defaultValue": 255,
"allowManualEntry": false,
"options": [
{
"label": "All on is not active all off is not active",
"value": 0
},
{
"label": "All on is not active all off active",
"value": 1
},
{
"label": "All on is not active all off is not active",
"value": 2
},
{
"label": "All on active, all off active",
"value": 255
}
]
},
{
"#": "40",
"label": "Power Reporting in Watts on Power Change",
"description": "Power consumption change threshold for sending updates",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 1
},
{
"#": "42",
"label": "Power Reporting in Watts by Time Interval",
"valueSize": 2,
"unit": "seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 300
},
{
"#": "71",
"label": "Operating Modes",
"description": "Operation Mode (Shutter or Venetian)",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Shutter mode",
"value": 0
},
{
"label": "Venetian mode (Up/Down and slate rotation)",
"value": 1
}
]
},
{
"#": "72",
"label": "Slats Tilting Full Turn Time",
"description": "Slat full turn time in tenths of a second.",
"valueSize": 2,
"unit": "tenths of a seconds",
"minValue": 0,
"maxValue": 32767,
"defaultValue": 150
},
{
"#": "73",
"label": "Slats Position",
"description": "Slats position after up/down movement.",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Previous position for Z-Wave control only",
"value": 0
},
{
"label": "Return to previous position in all cases",
"value": 1
}
]
},
{
"#": "74",
"label": "Motor Moving Up/down Time",
"description": "Shutter motor moving time of complete opening or complete closing",
"valueSize": 2,
"minValue": 0,
"maxValue": 32767,
"defaultValue": 0
},
{
"#": "76",
"label": "Motor Operation Detection",
"description": "Power threshold to be interpreted when motor reach the limit switch",
"valueSize": 1,
"minValue": 0,
"maxValue": 127,
"defaultValue": 10
},
{
"#": "78",
"label": "Forced Shutter Calibration",
"description": "Enters calibration mode if set to 1",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Default",
"value": 0
},
{
"label": "Start calibration process",
"value": 1
}
]
},
{
"#": "80",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Reporting to Controller",
"description": "Defines if reporting regarding power level, etc is reported to controller.",
"defaultValue": 1
},
{
"#": "85",
"label": "Power Consumption Max Delay Time",
"description": "Time delay for detecting motor errors",
"valueSize": 1,
"minValue": 0,
"maxValue": 50,
"defaultValue": 8
},
{
"#": "86",
"label": "Power Consumption At Limit Switch Delay Time",
"description": "Sets the time delay for detecting limit switches",
"valueSize": 1,
"minValue": 3,
"maxValue": 50,
"defaultValue": 8
},
{
"#": "90",
"label": "Relay Delay Time",
"description": "Defines the minimum time delay between next motor movement",
"valueSize": 1,
"unit": "ms",
"minValue": 1,
"maxValue": 30,
"defaultValue": 5
},
{
"#": "110",
"label": "Temperature Sensor Offset Settings",
"description": "Adds or removes an offset from the measured temperature.",
"valueSize": 2,
"minValue": 1,
"maxValue": 32536,
"defaultValue": 32536
},
{
"#": "120",
"label": "Digital Temperature Sensor Reporting",
"description": "Threshold for sending temperature change reports",
"valueSize": 1,
"minValue": 0,
"maxValue": 127,
"defaultValue": 5
}
],
"metadata": {
"inclusion": "Module Inclusion (Adding to Z-wave network)\n• Connect module to power supply (with \ntemperature sensor connected - if purchased),\n• auto-inclusion (works for about 5 seconds after connected to power supply) or\n• press push button I1 three times within 3s (3 times change switch state within 3 seconds) or\n• press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.\nNOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.\nNOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.",
"exclusion": "Module Exclusion (Removing from Z-Wave network)\n• Connect module to power supply \n• bring module within maximum 1 meter (3 feet) of the main controller,\n• enable add/remove mode on main controller\nIf push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to their default values.",
"reset": "• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or\n• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.\nBy this function all parameters of the module are set to their default values and the ID of the device is deleted.\nNOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.\nNOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2962/Manual_Devolo_HC%20Shutter_FM.pdf"
}
}