"manufacturer": "Devolo",
|
||
|
"manufacturerId": "0x0175",
|
||
|
"label": "MT02792",
|
||
|
"description": "Home Control Metering Plug",
|
||
|
"devices": [
|
||
|
{
|
||
|
"productType": "0x0001",
|
||
|
"productId": "0x0012"
|
||
|
}
|
||
|
],
|
||
|
"firmwareVersion": {
|
||
|
"min": "0.0",
|
||
|
"max": "255.255"
|
||
|
},
|
||
|
"paramInformation": [
|
||
|
{
|
||
|
"#": "1",
|
||
|
"label": "Watt Counter Reporting Period",
|
||
|
"description": "multiples of 5s",
|
||
|
"valueSize": 2,
|
||
|
"unit": "seconds",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 32767,
|
||
|
"defaultValue": 720,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "Disable",
|
||
|
"value": 0
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "2",
|
||
|
"label": "KWh Counter Reporting Period",
|
||
|
"description": "number of 10 minute intervals",
|
||
|
"valueSize": 2,
|
||
|
"unit": "10m",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 32767,
|
||
|
"defaultValue": 6,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "Disable",
|
||
|
"value": 0
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "3",
|
||
|
"label": "Definition of Warning of Current Load (A)",
|
||
|
"description": "1300*0.01A = 13A",
|
||
|
"valueSize": 2,
|
||
|
"unit": "0.01A",
|
||
|
"minValue": 10,
|
||
|
"maxValue": 1300,
|
||
|
"defaultValue": 1300
|
||
|
},
|
||
|
{
|
||
|
"#": "4",
|
||
|
"label": "Load Caution Threshold",
|
||
|
"valueSize": 2,
|
||
|
"minValue": 1,
|
||
|
"maxValue": 10000,
|
||
|
"defaultValue": 10000
|
||
|
},
|
||
|
{
|
||
|
"#": "5",
|
||
|
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev_on"
|
||
|
},
|
||
|
{
|
||
|
"#": "6",
|
||
|
"label": "Switch OFF Mode",
|
||
|
"description": "Mode of switch off function.",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 1,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "Switch off commands received are ignored",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "Switch off commands received are honored",
|
||
|
"value": 1
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "7",
|
||
|
"label": "LED Display Mode",
|
||
|
"description": "Display device status",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 1,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "The LED follows the state of the switch",
|
||
|
"value": 1
|
||
|
},
|
||
|
{
|
||
|
"label": "LED off with load on",
|
||
|
"value": 2
|
||
|
},
|
||
|
{
|
||
|
"label": "Flash mode",
|
||
|
"value": 3
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "8",
|
||
|
"label": "Auto Off Timer",
|
||
|
"description": "Auto off timer. 0 will disable the auto off function.",
|
||
|
"valueSize": 2,
|
||
|
"unit": "1s",
|
||
|
"minValue": 0,
|
||
|
"maxValue": 32767,
|
||
|
"defaultValue": 0,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "Disable",
|
||
|
"value": 0
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "9",
|
||
|
"label": "Device From Command Status",
|
||
|
"description": "RF off command mode",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 0,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "When all off is received, MT2792 goes off",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "Ignore all off",
|
||
|
"value": 1
|
||
|
},
|
||
|
{
|
||
|
"label": "If all off is received, turn on if it is off",
|
||
|
"value": 2
|
||
|
},
|
||
|
{
|
||
|
"label": "WhenALL off is received, the MT2792 goes on",
|
||
|
"value": 3
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
]
|
||
|
}
|