2025-01-10 22:05:04 -08:00
{
"manufacturer": "Fantem",
"manufacturerId": "0x016a",
"label": "FT132",
"description": "Dual Nano Switch with Energy Metering",
"devices": [
{
"productType": "0x0003",
"productId": "0x008c"
},
{
"productType": "0x0203",
"productId": "0x0084"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "3",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Current Overload Protection",
"defaultValue": 1
},
{
"#": "4",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Overheat Protection"
},
{
"#": "20",
"$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off"
},
{
"#": "80",
"label": "Group 1 Notifications",
"description": "To set which notification would be sent to the associated devices (Group 1)",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Send nothing",
"value": 0
},
{
"label": "Send Hail CC",
"value": 1
},
{
"label": "Send Basic CC Report",
"value": 2
},
{
"label": "Send Hail CC when using the manual switch",
"value": 3
}
]
},
{
"#": "81",
"label": "Group 3 Notifications",
"description": "To set which notification would be sent to association group 3",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Send nothing",
"value": 0
},
{
"label": "Send Basic Set cc",
"value": 1
}
]
},
{
"#": "82",
"label": "Group 4 Notifications",
"description": "To set which notification would be sent to association group 4",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Send nothing",
"value": 0
},
{
"label": "Send Basic CC Set",
"value": 1
}
]
},
{
"#": "90",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Enable/disable Parameters 91 and 92"
},
{
"#": "91",
"label": "Set the Threshold Value of Wattage",
"valueSize": 2,
"minValue": 0,
"maxValue": 60000,
"defaultValue": 25,
"unsigned": true
},
{
"#": "92",
"label": "Set the Threshold Value of Percent Power",
"valueSize": 1,
"minValue": 0,
"maxValue": 100,
"defaultValue": 5
},
{
"#": "100",
"label": "Set Parameter 101-103 to Default Value",
"description": "Reset the parameter 101-103",
"valueSize": 1,
"minValue": 0,
"maxValue": 0,
"defaultValue": 0,
"writeOnly": true
},
{
"#": "101",
"label": "Set Group 1 Reports",
"description": "To set which reports need to be sent in Report group 1",
"valueSize": 4,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Send Meter Report of energy (kWh)",
"value": 1
},
{
"label": "Send Meter Report of wattage (W)",
"value": 2
},
{
"label": "Send Meter Report of voltage (V)",
"value": 4
},
{
"label": "Send Meter Report of current (A)",
"value": 8
},
{
"label": "Meter Report of wattage (W) on channel 1",
"value": 256
},
{
"label": "Meter Report of wattage (W) on channel 2",
"value": 512
},
{
"label": "Meter Report of energy (kWh) on channel 1",
"value": 2048
},
{
"label": "Meter Report of energy (kWh) on channel 2",
"value": 4096
},
{
"label": "Meter Report of voltage (V) on channel 1",
"value": 65536
},
{
"label": "Meter Report of voltage (V) on channel 2",
"value": 131072
},
{
"label": "Meter Report of current (A) on channel 1",
"value": 524288
},
{
"label": "Meter Report of current (A) on channel 2",
"value": 1048576
}
]
},
{
"#": "102",
"label": "Reports Sent to Report Group 2",
"valueSize": 4,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Send Meter Report of energy (kWh)",
"value": 1
},
{
"label": "Send Meter Report of wattage (W)",
"value": 2
},
{
"label": "Send Meter Report of voltage (V)",
"value": 4
},
{
"label": "Send Meter Report of current (A)",
"value": 8
},
{
"label": "Meter Report of wattage (W) on channel 1",
"value": 256
},
{
"label": "Meter Report of wattage (W) on channel 2",
"value": 512
},
{
"label": "Meter Report of energy (kWh) on channel 1",
"value": 2048
},
{
"label": "Meter Report of energy (kWh) on channel 2",
"value": 4096
},
{
"label": "Meter Report of voltage (V) on channel 1",
"value": 65536
},
{
"label": "Meter Report of voltage (V) on channel 2",
"value": 131072
},
{
"label": "Meter Report of current (A) on channel 1",
"value": 524288
},
{
"label": "Meter Report of current (A) on channel 2",
"value": 1048576
}
]
},
{
"#": "103",
"label": "Reports Sent to Report Group 3",
"valueSize": 4,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Send Meter Report of voltage (V)",
"value": 1
},
{
"label": "Send Meter Report of current (A)",
"value": 2
},
{
"label": "Send Meter Report of wattage (W)",
"value": 4
},
{
"label": "Send Meter Report of energy (kWh)",
"value": 8
},
{
"label": "Meter Report of wattage (W) on channel 1",
"value": 256
},
{
"label": "Meter Report of wattage (W) on channel 2",
"value": 512
},
{
"label": "Meter Report of energy (kWh) on channel 1",
"value": 2048
},
{
"label": "Meter Report of energy (kWh) on channel 2",
"value": 4096
},
{
"label": "Meter Report of voltage (V) on channel 1",
"value": 65536
},
{
"label": "Meter Report of voltage (V) on channel 2",
"value": 131072
},
{
"label": "Meter Report of current (A) on channel 1",
"value": 524288
},
{
"label": "Meter Report of current (A) on channel 2",
"value": 1048576
}
]
},
{
"#": "110",
"label": "Set Parameter 111-113 to Default Value",
"valueSize": 1,
"minValue": 0,
"maxValue": 0,
"defaultValue": 0,
"writeOnly": true
},
{
"#": "111",
"label": "Automatic Report Interval for Report Group 1",
"valueSize": 4,
"minValue": 1,
"maxValue": 2147483647,
"defaultValue": 10
},
{
"#": "112",
"label": "Automatic Report Interval for Report Group 2",
"valueSize": 4,
"minValue": 1,
"maxValue": 2147483647,
"defaultValue": 600
},
{
"#": "113",
"label": "Automatic Report Interval for Report Group 3",
"valueSize": 4,
"minValue": 1,
"maxValue": 2147483647,
"defaultValue": 600
},
{
"#": "120",
"label": "Configure the External Switch Mode for S1",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Enter automatic identification mode",
"value": 0
},
{
"label": "2-State switch mode",
"value": 1
},
{
"label": "3 way switch mode",
"value": 2
},
{
"label": "Momentary push button mode",
"value": 3
}
]
},
{
"#": "121",
"label": "Configure the External Switch Mode for S2",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Enter automatic identification mode",
"value": 0
},
{
"label": "2-State switch mode",
"value": 1
},
{
"label": "3 way switch mode",
"value": 2
},
{
"label": "Momentary push button mode",
"value": 3
}
]
},
{
"#": "122",
"label": "Set the Control Destination for External Switch",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Control the output loads of itself",
"value": 1
},
{
"label": "Control the other nodes",
"value": 2
},
{
"label": "Control the output of itself and others",
"value": 3
}
]
},
{
"#": "252",
"label": "Lock/unlock Configuration Parameters",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Unlock",
"value": 0
},
{
"label": "Lock",
"value": 1
}
]
},
{
"#": "255",
"label": "Reset the Dual Nano Switch",
"valueSize": 4,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Reset all configuration parameters",
"value": 0
},
{
"label": "Reset & remove from network",
"value": 1431655765
}
]
}
]
}