zwave-js/.config-db/devices/0x015f/mh-s220_0.0-3.1.json

170 lines
3 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "McoHome Technology Co., Ltd.",
"manufacturerId": "0x015f",
"label": "MH-S220",
"description": "Micro Switch",
"devices": [
{
"productType": "0x2201",
"productId": "0x1252"
},
{
"productType": "0x2201",
"productId": "0x7202"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "3.1"
},
"associations": {
"1": {
"label": "Switch 1",
"maxNodes": 5
},
"2": {
"label": "Switch 2",
"maxNodes": 5
},
"3": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
},
{
"#": "2",
"label": "External Switch Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Momentary buttons",
"value": 0
},
{
"label": "Toggle switches",
"value": 1
}
]
},
{
"#": "3",
"label": "Toggle Switch Behavior",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Without specified on/off position",
"value": 0
},
{
"label": "With specified on/off position",
"value": 1
}
]
},
{
"#": "4",
"label": "Switch 1: Report to Association Group 1",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Report both on/off",
"value": 0
},
{
"label": "Report on only",
"value": 1
},
{
"label": "Report off only",
"value": 2
}
]
},
{
"#": "5",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Switch 1: Off Timer",
"defaultValue": 1
},
{
"#": "6",
"label": "Switch 1: Off Timer Interval",
"valueSize": 2,
"unit": "100ms",
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true
},
{
"#": "7",
"label": "Operation Mode",
"description": "Determines if relay switches when command is received, or when AC voltage next crosses 0V. Zero crossing mode may reduce possibility of relay failure.",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Switch immediately",
"value": 0
},
{
"label": "Zero crossing detection",
"value": 1
}
]
},
{
"#": "8",
"label": "Switch 2: Operation Report to Association Group 2",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Report both on/off",
"value": 0
},
{
"label": "Report on only",
"value": 1
},
{
"label": "Report off only",
"value": 2
}
]
},
{
"#": "255",
"label": "Factory Reset",
"valueSize": 1,
"defaultValue": 0,
"writeOnly": true,
"allowManualEntry": false,
"options": [
{
"label": "Idle",
"value": 0
},
{
"label": "Factory reset",
"value": 85
}
]
}
]
}