zwave-js/.config-db/devices/0x015f/mh-p220.json

316 lines
6.8 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "McoHome Technology Co., Ltd.",
"manufacturerId": "0x015f",
"label": "MH-P220",
"description": "Micro Dimmer",
"devices": [
{
"productType": "0x220a",
"productId": "0x1352"
},
{
"productType": "0x220a",
"productId": "0x5101",
"zwaveAllianceId": 3011
},
{
"productType": "0x220a",
"productId": "0x5102"
},
{
"productType": "0x220a",
"productId": "0x5103"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
},
{
"#": "2",
"label": "External Switch Type",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Momentary",
"value": 0
},
{
"label": "Switch",
"value": 1
},
{
"label": "Roller blind switch - S1 -> up; S2 -> down",
"value": 2
}
]
},
{
"#": "3",
"label": "Switch States",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Toggle",
"value": 0
},
{
"label": "On/Off switch",
"value": 1
}
]
},
{
"#": "4",
"label": "All On / All Off",
"valueSize": 1,
"defaultValue": 255,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Enable all off; Disable all on",
"value": 1
},
{
"label": "Enable all on; Disable all off",
"value": 2
},
{
"label": "Enable",
"value": 255
}
]
},
{
"#": "5",
"label": "Minimum Brightness",
"valueSize": 1,
"minValue": 1,
"maxValue": 98,
"defaultValue": 1
},
{
"#": "6",
"label": "Maximum Brightness",
"valueSize": 1,
"minValue": 2,
"maxValue": 99,
"defaultValue": 99
},
{
"#": "7",
"label": "Dimming Step Time (Manual)",
"valueSize": 2,
"unit": "10ms",
"minValue": 1,
"maxValue": 255,
"defaultValue": 3
},
{
"#": "8",
"label": "Dimming Step Size (Manual)",
"valueSize": 1,
"minValue": 1,
"maxValue": 99,
"defaultValue": 1
},
{
"#": "9",
"label": "Dimming Step Time (Auto)",
"valueSize": 2,
"unit": "10ms",
"minValue": 1,
"maxValue": 255,
"defaultValue": 3
},
{
"#": "10",
"label": "Dimming Step Size (Auto)",
"valueSize": 1,
"minValue": 1,
"maxValue": 99,
"defaultValue": 1
},
{
"#": "11",
"label": "Auto-Off Timer",
"valueSize": 2,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0
},
{
"#": "13",
"label": "One Click of S1",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 99
},
{
"#": "14",
"label": "Double Click of S1",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Max brightness",
"value": 1
}
]
},
{
"#": "15",
"label": "Operation Report Switch1 to Association Groups 2 & 3",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "16",
"label": "Operation Report Switch1 to Association Group 2",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "On = 0xff",
"value": 0
},
{
"label": "On = current dimmer value",
"value": 1
}
]
},
{
"#": "17",
"label": "Switch 2 Function",
"valueSize": 1,
"defaultValue": 1,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Wire with roller blinds switch",
"value": 0
},
{
"label": "Scene Activation; Control association group 4",
"value": 1
},
{
"label": "Scene Activation",
"value": 2
},
{
"label": "Send Basic CC Set",
"value": 3
},
{
"label": "Disable",
"value": 255
}
]
},
{
"#": "18",
"label": "Association Group 4 Commands",
"valueSize": 1,
"defaultValue": 0,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "Basic CC Set (On/Off)",
"value": 0
},
{
"label": "Basic CC Set (On)",
"value": 1
},
{
"label": "Basic CC Set (Off)",
"value": 2
},
{
"label": "Disable",
"value": 255
}
]
},
{
"#": "19",
"label": "Scene ID - One Click of S2 (Association Group 1)",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "20",
"label": "Scene ID - Double Click of S2 (Association Group 1)",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "21",
"label": "Scene ID - Hold of S2 (Association Group 1)",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "255",
"label": "Factory Reset",
"valueSize": 1,
"defaultValue": 0,
"writeOnly": true,
"allowManualEntry": false,
"options": [
{
"label": "Normal operation",
"value": 0
},
{
"label": "Factory reset",
"value": 85
}
]
}
],
"metadata": {
"inclusion": "Add the device into Z-Wave network:\n1. Set controller into ADD mode. Follow the instructions provided by the controller/gateway manufacturer.\n2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession. \nNote: If the ADD is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switchs state.",
"exclusion": "Remove the device from Z-Wave network:\n1. Set controller into REMOVE mode. Follow the instructions provided by the controller/gateway manufacturer.\n2. Press the momentary button on the device 3 times, or the connected external button S1 3 times in quick succession. \nNote: If the REMOVE is successful, the INDICATION LED will blink 6 times. If not, INDICATION LED will be solid on or off depending on switchs state.",
"reset": "Restoring Factory Settings:\nThe default configuration can be restored by:\n Sending commands through controller/gateway (the command classes which support this function is Configuration Command Class). The parameter are as follows:\n\nParameter Number 0xFF\nSize 1 BYTE\nDefault value N/A\nConfiguration value 0x55\nSet 0xFF as 0x55 will restore Factory Settings.\n\n Or press the inner button on the module 10 times in quick succession.Please use this procedure only when the network primary controller is missing or otherwise inoperable.",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/3011/MH-P220UserManual.pdf"
}
}