zwave-js/.config-db/devices/0x010f/fgs221.json

548 lines
10 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Fibargroup",
"manufacturerId": "0x010f",
"label": "FGS221",
"description": "Double Relay Switch 2x1.5kW",
"devices": [
{
"productType": "0x0200",
"productId": "0x0102",
"zwaveAllianceId": [29, 46]
},
{
"productType": "0x0200",
"productId": "0x0103"
},
{
"productType": "0x0200",
"productId": "0x0104"
},
{
"productType": "0x0200",
"productId": "0x0105"
},
{
"productType": "0x0200",
"productId": "0x0106"
},
{
"productType": "0x0200",
"productId": "0x0107"
},
{
"productType": "0x0200",
"productId": "0x0109"
},
{
"productType": "0x0200",
"productId": "0x100a"
},
{
"productType": "0x0200",
"productId": "0x300a"
},
{
"productType": "0x0202",
"productId": "0x3002"
},
{
"productType": "0x0200",
"productId": "0x400a"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Switch 1",
"maxNodes": 16
},
"2": {
"label": "Switch 2",
"maxNodes": 16
},
"3": {
"label": "Controller Updates",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Enable/Disable ALL ON/OFF",
"valueSize": 1,
"defaultValue": 255,
"unsigned": true,
"allowManualEntry": false,
"options": [
{
"label": "All on disabled/ all off disabled",
"value": 0
},
{
"label": "All on disabled/ all off active",
"value": 1
},
{
"label": "All on active / All off disabled",
"value": 2
},
{
"label": "All on active / All off active",
"value": 255
}
]
},
{
"#": "3",
"$if": "firmwareVersion <= 2.0",
"label": "Enable/Disable OFF-Delay",
"description": "Activate/Deactivate Automatic turning off relay after set time",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Auto off disabled for both relays",
"value": 0
},
{
"label": "Auto off active only for relay 1",
"value": 1
},
{
"label": "Auto off active only for relay 2",
"value": 2
},
{
"label": "Auto off active for both relays",
"value": 3
}
]
},
{
"#": "3",
"$if": "firmwareVersion >= 2.1",
"label": "Auto Off Relay After Specified Time",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Manual override disabled",
"value": 0
},
{
"label": "Manual override enabled",
"value": 1
}
]
},
{
"#": "4",
"$if": "firmwareVersion <= 1.8",
"label": "Relay 1: OFF-Delay Time (10ms Steps)",
"description": "Automatic turning off relay 1 after set time",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 20,
"unsigned": true
},
{
"#": "4",
"$if": "firmwareVersion >= 1.9",
"label": "Relay 1: OFF-Delay Time",
"description": "Automatic turning off relay 1 after set time in milliseconds, 0 to disable",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true
},
{
"#": "5",
"$if": "firmwareVersion <= 1.8",
"label": "Relay 2: OFF-Delay Time (10ms Steps)",
"description": "Automatic turning off relay 2 after set time",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 20,
"unsigned": true
},
{
"#": "5",
"$if": "firmwareVersion >= 1.9",
"label": "Relay 2: OFF-Delay Time",
"description": "Automatic turning off relay 2 after set time in milliseconds, 0 to disable",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 0,
"unsigned": true
},
{
"#": "6",
"label": "Sending Commands to Group 1 Devices",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Commands are sent when device is turned on and off",
"value": 0
},
{
"label": "Commands sent when device off with memorized state",
"value": 1
},
{
"label": "Commands are sent when device is turned off",
"value": 2
}
]
},
{
"#": "7",
"$if": "firmwareVersion <= 1.8",
"label": "Separation of Association Sending (Key 2)",
"description": "Activate/Deactivate association sending for group 2",
"valueSize": 1,
"defaultValue": 0,
"writeOnly": true,
"allowManualEntry": false,
"options": [
{
"label": "Map status to all devices in group 2",
"value": 0
},
{
"label": "Map off status to devices in group 2-last state",
"value": 1
},
{
"label": "Map off status to devices in grp 2-full brightness",
"value": 2
}
]
},
{
"#": "7",
"$if": "firmwareVersion >= 1.9 && firmwareVersion <= 2.0",
"label": "Control Key #2 Behaviour",
"description": "Map status to devices in group 2.",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Device status is not checked",
"value": 0
},
{
"label": "Device status is checked",
"value": 1
}
]
},
{
"#": "7",
"$if": "firmwareVersion >= 2.1",
"label": "Sending Commands to Group 2 Devices",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Commands are sent when device is turned on and off",
"value": 0
},
{
"label": "Commands sent when device off with memorized state",
"value": 1
},
{
"label": "Commands are sent when device is turned off",
"value": 2
}
]
},
{
"#": "13",
"label": "Inputs Behaviour",
"description": "In case of bi-stable switches, define their behaviour (toggle or follow)",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Toggle",
"value": 0
},
{
"label": "Follow switch contact (Closed=ON, open=OFF)",
"value": 1
}
]
},
{
"#": "14",
"label": "Switch Type Connector",
"description": "Switch type connector, you may choose between momentary and toggle switches",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Momentary switch",
"value": 0
},
{
"label": "Toggle switch",
"value": 1
}
]
},
{
"#": "15",
"label": "Dimmer/Roller Shutter Control",
"description": "Enable/Disable operation associated to group 1",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Disable dimmer/roller shutter control",
"value": 0
},
{
"label": "Enable dimmer/roller shutter control",
"value": 1
}
]
},
{
"#": "16",
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
},
{
"#": "30",
"label": "Relay 1: Response to General Alarm",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 1",
"value": 0
},
{
"label": "Alarm relay 1 on",
"value": 1
},
{
"label": "Alarm relay 1 off",
"value": 2
},
{
"label": "Alarm relay 1 flashing",
"value": 3
}
]
},
{
"#": "31",
"label": "Relay 1: Response to Water Flood Alarm",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 1",
"value": 0
},
{
"label": "Alarm relay 1 on",
"value": 1
},
{
"label": "Alarm relay 1 off",
"value": 2
},
{
"label": "Alarm relay 1 flashing",
"value": 3
}
]
},
{
"#": "32",
"label": "Relay 1: Response to Smoke, CO, CO2 Alarm",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 1",
"value": 0
},
{
"label": "Alarm relay 1 on",
"value": 1
},
{
"label": "Alarm relay 1 off",
"value": 2
},
{
"label": "Alarm relay 1 flashing",
"value": 3
}
]
},
{
"#": "33",
"label": "Relay 1: Response to Temperature Alarm",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 1",
"value": 0
},
{
"label": "Alarm relay 1 on",
"value": 1
},
{
"label": "Alarm relay 1 off",
"value": 2
},
{
"label": "Alarm relay 1 flashing",
"value": 3
}
]
},
{
"#": "39",
"label": "ALARM FLASHING Alarm Time",
"description": "Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 600,
"unsigned": true
},
{
"#": "40",
"label": "Relay 2: Response to General Alarm",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 2",
"value": 0
},
{
"label": "Alarm relay 2 on",
"value": 1
},
{
"label": "Alarm relay 2 off",
"value": 2
},
{
"label": "Alarm relay 2 flashing",
"value": 3
}
]
},
{
"#": "41",
"label": "Relay 2: Response to Water Flood Alarm",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 2",
"value": 0
},
{
"label": "Alarm relay 2 on",
"value": 1
},
{
"label": "Alarm relay 2 off",
"value": 2
},
{
"label": "Alarm relay 2 flashing",
"value": 3
}
]
},
{
"#": "42",
"label": "Relay 2: Response to Smoke, CO, CO2 Alarm",
"valueSize": 1,
"defaultValue": 3,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 2",
"value": 0
},
{
"label": "Alarm relay 2 on",
"value": 1
},
{
"label": "Alarm relay 2 off",
"value": 2
},
{
"label": "Alarm relay 2 flashing",
"value": 3
}
]
},
{
"#": "43",
"label": "Relay 2: Response to Temperature Alarm",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Alarm deactivation relay 2",
"value": 0
},
{
"label": "Alarm relay 2 on",
"value": 1
},
{
"label": "Alarm relay 2 off",
"value": 2
},
{
"label": "Alarm relay 2 flashing",
"value": 3
}
]
}
],
"compat": {
// The device sends reports for endpoint 1 un-encapsulated
"mapRootReportsToEndpoint": 1
}
}