2025-01-10 22:05:04 -08:00
{
"manufacturer": "Fibargroup",
"manufacturerId": "0x010f",
"label": "FGD212",
"description": "Dimmer 2",
"devices": [
{
"productType": "0x0102",
"productId": "0x1000"
},
{
"productType": "0x0102",
"productId": "0x1001"
},
{
"productType": "0x0102",
"productId": "0x2000"
},
{
"productType": "0x0102",
"productId": "0x3000"
},
{
"productType": "0x0102",
"productId": "0x4000"
},
{
"productType": "0x0102",
"productId": "0x6000"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
},
"2": {
"label": "Send BASIC SET command class frame S1",
"maxNodes": 10
},
"3": {
"label": "Sends MULTILEVEL SWITCH command class frame S1",
"maxNodes": 10
},
"4": {
"label": "Sends BASIC SET command class S2",
"maxNodes": 10
},
"5": {
"label": "Sends MULTILEVEL SWITCH command class frame S2",
"maxNodes": 10
}
},
"paramInformation": [
{
"#": "1",
"label": "Minimum Brightness Level",
"description": "For manual override, this is set during auto-calibration",
"valueSize": 1,
"minValue": 1,
"maxValue": 98,
"defaultValue": 1
},
{
"#": "2",
"$if": "firmwareVersion <= 3.4",
"label": "Maximum Brightness Level",
"description": "For manual override, this is set during auto-calibration",
"valueSize": 1,
"minValue": 1,
"maxValue": 99,
"defaultValue": 99
},
{
"#": "2",
"$if": "firmwareVersion >= 3.5",
"label": "Maximum Brightness Level",
"description": "For manual override, this is set during auto-calibration",
"valueSize": 1,
"minValue": 2,
"maxValue": 99,
"defaultValue": 99
},
{
"#": "3",
"label": "Incandescence Level of Dimmable CFL",
"description": "Relative to the range defined by minimum and maximum brightness level configuration",
"valueSize": 1,
"minValue": 1,
"maxValue": 99,
"defaultValue": 1
},
{
"#": "4",
"label": "Incandescence Time of Dimmable CFL",
"valueSize": 2,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0
},
{
"#": "5",
"label": "Automatic Control: Dimming Step Size",
"valueSize": 1,
"minValue": 1,
"maxValue": 99,
"defaultValue": 1
},
{
"#": "6",
"label": "Automatic Control: Dimming Step Timing",
"valueSize": 2,
"minValue": 0,
"maxValue": 255,
"defaultValue": 1
},
{
"#": "7",
"label": "Manual Control: Dimming Step Size",
"description": "Relative to the range defined by minimum and maximum brightness level configuration",
"valueSize": 1,
"minValue": 1,
"maxValue": 99,
"defaultValue": 1
},
{
"#": "8",
"label": "Manual Control: Dimming Step Timing",
"valueSize": 2,
"minValue": 0,
"maxValue": 255,
"defaultValue": 5
},
{
"#": "9",
"$import": "~/templates/master_template.json#state_after_power_failure_off_prev"
},
{
"#": "10",
"label": "Timer Functionality (Auto - Off)",
"description": "Will automatically turn off after the specified time from switching on",
"valueSize": 2,
"minValue": 0,
"maxValue": 32767,
"defaultValue": 0
},
{
"#": "11",
"label": "ALL ON/ALL OFF Function",
"valueSize": 2,
"defaultValue": 255,
"allowManualEntry": false,
"options": [
{
"label": "All on not active, all off not active",
"value": 0
},
{
"label": "All on not active, all off active",
"value": 1
},
{
"label": "All on active, all off not active",
"value": 2
},
{
"label": "All on active, all off active",
"value": 255
}
]
},
{
"#": "13",
"label": "Force Auto-Calibration",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Readout",
"value": 0
},
{
// eslint-disable-next-line @zwave-js/consistent-config-string-case
"label": "Force auto-calibration without Fibaro Bypass",
"value": 1
},
{
// eslint-disable-next-line @zwave-js/consistent-config-string-case
"label": "Force auto-calibration with Fibaro Bypass",
"value": 2
}
]
},
{
"#": "14",
"label": "Auto-Calibration Status",
"valueSize": 1,
"minValue": 0,
"maxValue": 1,
"defaultValue": 0,
"readOnly": true,
"options": [
{
"label": "No calibration on manual setting",
"value": 0
},
{
"label": "Dimmer operates on auto-calibration settings",
"value": 1
}
]
},
{
"#": "15",
"label": "Burnt Out Bulb Detection Power Variation",
"description": "Percentage value of standard power consumption as measured during calibration",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 30,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "16",
"label": "Burnt Out Bulb Detection Time Delay",
"valueSize": 2,
"minValue": 0,
"maxValue": 255,
"defaultValue": 5,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "19",
"label": "Forced Switch On Brightness",
"description": "Relative to the range defined by minimum and maximum brightness level configuration",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 0,
"options": [
{
"label": "Previous level",
"value": 0
}
]
},
{
"#": "20",
"label": "Input Button/Switch Configuration",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Momentary",
"value": 0
},
{
"label": "Toggle",
"value": 1
},
{
"label": "Roller blind switch (Up / Down)",
"value": 2
}
]
},
{
"#": "21",
"label": "Value Sent to Associated Devices On Single Click",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Set associated devices to last state",
"value": 0
},
{
"label": "This dimmer's current brightness",
"value": 1
}
]
},
{
"#": "22",
"label": "Change Toggle Switch Behavior",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Output changes on input switch change",
"value": 0
},
{
"label": "Output syncs with input switch position",
"value": 1
}
]
},
{
"#": "23",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Double Click Sets Brightness to 100%",
"defaultValue": 1
},
{
"#": "24[0x01]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s1_associations_on"
},
{
"#": "24[0x02]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s1_associations_off"
},
{
"#": "24[0x04]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s1_associations_hold_release"
},
{
"#": "24[0x08]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s1_associations_double_click"
},
{
"#": "24[0x10]",
"$if": "firmwareVersion >= 3.5",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Send Command Frames in 2nd and 3rd Association Groups with 0xFF Value On Double Click"
},
{
"#": "25[0x01]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s2_associations_on"
},
{
"#": "25[0x02]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s2_associations_off"
},
{
"#": "25[0x04]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s2_associations_hold_release"
},
{
"#": "25[0x08]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_s2_associations_double_click"
},
{
"#": "25[0x10]",
"$if": "firmwareVersion >= 3.5",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Send Command Frames in 4th and 5th Association Groups with 0xFF Value On Double Click"
},
{
"#": "26",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "3-Way Switch Function",
"description": "Key S2 also controls the dimmer"
},
{
"#": "27[0x01]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_secure_commands_group2",
"defaultValue": 1
},
{
"#": "27[0x02]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_secure_commands_group3",
"defaultValue": 1
},
{
"#": "27[0x04]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_secure_commands_group4",
"defaultValue": 1
},
{
"#": "27[0x08]",
"$if": "firmwareVersion >= 3.5",
"$import": "templates/fibaro_template.json#send_secure_commands_group5",
"defaultValue": 1
},
{
"#": "28",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Scene Activation Functionality",
"description": "See manual for SCENE ID specification details"
},
{
"#": "29",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Swap Functionality of Key S1 and Key S2",
"description": "Causes S1 to operate as S2 and S2 to operate as S1"
},
{
"#": "30",
"label": "Dimmer Mode",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Force leading edge",
"value": 0
},
{
"label": "Force trailing edge",
"value": 1
},
{
"label": "As recognized during auto-calibration",
"value": 2
}
]
},
{
"#": "31",
"label": "Dimmer Mode Recognized During Auto-Calibration",
"valueSize": 1,
"minValue": 0,
"maxValue": 1,
"defaultValue": 0,
"readOnly": true,
"options": [
{
"label": "Leading edge",
"value": 0
},
{
"label": "Trailing edge",
"value": 1
}
]
},
{
"#": "32",
"label": "On/Off Mode",
"description": "Useful when connecting non-dimmable loads",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Disable (Dimming possible)",
"value": 0
},
{
"label": "Enable (Dimming not possible)",
"value": 1
},
{
"label": "As recognized during auto-calibration",
"value": 2
}
]
},
{
"#": "33",
"label": "Dimmability Recognized During Auto-Calibration",
"valueSize": 1,
"minValue": 0,
"maxValue": 1,
"defaultValue": 0,
"readOnly": true,
"options": [
{
"label": "Dimming possible",
"value": 0
},
{
"label": "Dimming not possible",
"value": 1
}
]
},
{
"#": "34",
"label": "Soft-Start Functionality",
"description": "Time required to warm up the filament of halogen bulb",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "No soft-start",
"value": 0
},
{
"label": "Short soft-start (0.1s)",
"value": 1
},
{
"label": "Long soft-start (0.5s)",
"value": 2
}
]
},
{
"#": "35",
"label": "Perform Auto-Calibration",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Never",
"value": 0
},
{
"label": "After first power on",
"value": 1
},
{
"label": "After each power on",
"value": 2
},
{
"label": "After first power up or each load error, surge or overcurrent",
"value": 3
},
{
"label": "After each power up or each load error, surge or overcurrent",
"value": 4
}
]
},
{
"#": "37",
"label": "Behavior After Overcurrent or Surge",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Device permanently disabled",
"value": 0
},
{
"label": "Three attempts to turn on the load",
"value": 1
}
]
},
{
"#": "38",
"$if": "firmwareVersion >= 3.5",
"label": "Brightness Level Correction for Flickering Loads",
"valueSize": 2,
"minValue": 0,
"maxValue": 255,
"defaultValue": 255,
"options": [
{
"label": "Disable",
"value": 0
},
{
"label": "Always enable",
"value": 255
}
]
},
{
"#": "39",
"$if": "firmwareVersion <= 3.4",
"label": "Power Limit",
"description": "Defined value turns off load",
"valueSize": 2,
"minValue": 0,
"maxValue": 250,
"defaultValue": 250
},
{
"#": "39",
"$if": "firmwareVersion >= 3.5",
"label": "Power Limit",
"description": "Defined value turns off load",
"valueSize": 2,
"minValue": 0,
"maxValue": 350,
"defaultValue": 250
},
{
"#": "40",
"$import": "templates/fibaro_template.json#general_purpose_alarm_response"
},
{
"#": "41",
"$import": "templates/fibaro_template.json#water_flood_alarm_response"
},
{
"#": "42",
"$import": "templates/fibaro_template.json#smoke_alarm_response"
},
{
"#": "43",
"$import": "templates/fibaro_template.json#temperature_alarm_response"
},
{
"#": "44",
"$import": "templates/fibaro_template.json#alarm_state_time",
"maxValue": 32767
},
{
"#": "45",
"label": "Power Limit Alarm Report",
"description": "Load power consumption too high",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "No reaction",
"value": 0
},
{
"label": "Send an alarm frame",
"value": 1
}
]
},
{
"#": "46",
"label": "Load Error Alarm Report",
"description": "No load, load failure, burnt out bulb",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "No reaction",
"value": 0
},
{
"label": "Send an alarm frame",
"value": 1
}
]
},
{
"#": "47",
"label": "Overcurrent Alarm Report",
"description": "Short circuit, burnt out bulb causing overcurrent",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "No reaction",
"value": 0
},
{
"label": "Send an alarm frame",
"value": 1
}
]
},
{
"#": "48",
"label": "Surge Alarm Report",
"description": "Dimmer output overvoltage",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "No reaction",
"value": 0
},
{
"label": "Send an alarm frame",
"value": 1
}
]
},
{
"#": "49",
"label": "Overheat and Voltage Drop Alarm Report",
"description": "Critical temperature and low voltage",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "No reaction",
"value": 0
},
{
"label": "Send an alarm frame",
"value": 1
}
]
},
{
"#": "50",
"$import": "templates/fibaro_template.json#power_report_threshold_relative",
"defaultValue": 10
},
{
"#": "52",
"$import": "templates/fibaro_template.json#reports_periodic",
"label": "Periodic Active Power and Energy Reports",
"maxValue": 32767
},
{
"#": "53",
"$import": "templates/fibaro_template.json#energy_report_threshold",
"maxValue": 255,
"defaultValue": 10
},
{
"#": "54",
"$import": "templates/fibaro_template.json#reports_include_self"
},
{
"#": "58",
"label": "Active Power Calculation Method",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Measurement based on the standard algorithm",
"value": 0
},
{
"label": "Approximation based on the calibration data",
"value": 1
},
{
"label": "Approximation based on the control angle",
"value": 2
}
]
},
{
"#": "59",
"label": "Approximated Power At the Maximum Brightness Level",
"valueSize": 2,
"minValue": 0,
"maxValue": 500,
"defaultValue": 0
}
],
"metadata": {
"$import": "templates/fibaro_template.json#default_metadata",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2836/FGD-212-EN-T-v1.3.pdf"
}
}