"manufacturer": "Good Way Technology Co., Ltd.",
"manufacturerId": "0x0068",
"label": "TD13320",
"description": "Smart Meter Switch",
"devices": [
{
"productType": "0x0003",
"productId": "0x0006",
"zwaveAllianceId": 2115
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "1",
"label": "Meter Report Interval",
"valueSize": 2,
"unit": "minutes",
"minValue": 0,
"maxValue": 255,
"defaultValue": 30
},
{
"#": "2",
"label": "Night Light Mode",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "3",
"label": "Night Light Color Value",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
}
],
"metadata": {
"inclusion": "If you want to manually include the device, press the button for 3 times to include the device.\nLED Status: Blue LED Solid light",
"exclusion": "If you want to manually exclude the device, press the button for 3 times to exclude the device.\nLED Status: Green LED 1 sec. flashes 1 times",
"reset": "The Device Reset Locally Notification Command is used to\nadvertise that the device will be reset to default.\nPress the button 3 times in 2 sec., and hold it for more\nthan 3 sec.\nPlease use this procedure only when the network primary\ncontroller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2115/TD13320_UserManual_2016_12_13.pdf"
}
}