2025-01-10 22:05:04 -08:00
{
"manufacturer": "Allegion",
"manufacturerId": "0x003b",
"label": "BE468ZP",
"description": "Schlage Connect Smart Deadbolt",
"devices": [
{
"productType": "0x0001",
"productId": "0x0468",
"zwaveAllianceId": [3028, 3707]
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "3",
"$import": "~/templates/master_template.json#base_enable_disable_255",
"label": "Beeper",
"defaultValue": 255
},
{
"#": "4",
"$import": "~/templates/master_template.json#base_enable_disable_255",
"label": "Vacation Mode",
"description": "Enabling this disables all user codes on the keypad."
},
{
"#": "5",
"$import": "~/templates/master_template.json#base_enable_disable_255",
"label": "Lock and Leave Mode",
"description": "Controls the use of the \"Schlage\" button on the keypad for single button push for throwing the deadbolt",
"defaultValue": 255
},
{
"#": "6",
"label": "User Slot Bit Field",
"valueSize": 4,
"minValue": 0,
"maxValue": 0,
"readOnly": true
},
{
"#": "12",
"label": "Get Electronic Transition Count",
"valueSize": 4,
"minValue": 0,
"maxValue": 0,
"readOnly": true
},
{
"#": "13",
"label": "Get Mechanical Transition Count",
"valueSize": 4,
"minValue": 0,
"maxValue": 0,
"readOnly": true
},
{
"#": "14",
"label": "Get Electronic Failed Count",
"valueSize": 4,
"minValue": 0,
"maxValue": 0,
"readOnly": true
},
{
"#": "15",
"$import": "~/templates/master_template.json#base_enable_disable_255",
"label": "Auto Lock",
"description": "Automatically throws the deadbolt 30 seconds after a valid user code has been entered at the keypad"
},
{
"#": "16",
"label": "User Code PIN Length",
"valueSize": 1,
"minValue": 4,
"maxValue": 8,
"defaultValue": 4
},
{
"#": "17",
"label": "Get Electrical High Preload Transition Count",
"valueSize": 4,
"minValue": 0,
"maxValue": 0,
"readOnly": true
},
{
"#": "18",
"label": "Get Bootloader Version",
"valueSize": 1,
"minValue": 0,
"maxValue": 0,
"readOnly": true
}
],
"metadata": {
"inclusion": "One-button Add lock to Z-Wave Network (Inclusion) \n\n1. Place your home automation system or panel into the “Add” or Inclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). \n2. Remove the battery cover of the deadbolt. \n3. Press then release the button on the PCB.\n4. An LED will flash amber indicating the “Add” or Inclusion process is in progress. \n• If the Security Scheme is Security 2 (S2), verify the DSK of the lock at the Z-Wave Controller. The PIN Code portion of the Z-Wave DSK will be needed.\n5. When a green LED turns ON, the “Add” or Inclusion has completed successfully. \n6. If a red LED turns ON, try repeating steps 1-3 \n \nInteractive Instruction for Add \nhttps://instructions.allegion.com/instr/86/2543",
"exclusion": "One-button Remove lock from Z-Wave Network (Exclusion) \n\n1. Place your home automation system or panel into the “Remove” or Exclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). \n2. Remove the battery cover of the deadbolt. \n3. Press then release the button on the PCB. \n4. An LED will flash amber indicating the “Remove” or Exclusion process is in progress. \n5. When a green LED flashes 3 times, the “Remove” or Exclusion process is completed successfully. \n6. If a red LED turns ON, try repeating steps 1-3 \n\nInteractive Instruction for Remove https://instructions.allegion.com/instr/86/2581",
"reset": "Steps for One-button Factory Default Reset \n\n1. Remove the battery cover of the deadbolt\n2. Press and hold the button on the PCB for 7 (seven) seconds. \nWhile holding the button pressed, after 1 sec LED will be lit for 2 sec. and turn OFF; continue to press and hold the button until the LED will be lit again and release the button.\n3. The LED will blink red three times and the green check on the touchscreen will blink if the Factory Default Reset is successful. \n4. To check that the lock was reset, press the Schlage Button and enter one of the Default User Codes. If the reset was successful, the Default User Codes will unlock the deadbolt. \nNOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3707/Connect_QSG_Add_Remove_FDR_Association.pdf"
}
}