zwave-js/.config-db/devices/0x0039/39349_39456_zw1002.json

48 lines
1.6 KiB
JSON
Raw Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Honeywell",
"manufacturerId": "0x0039",
"label": "39349 / 39456 / ZW1002",
"description": "In-Wall Outlet, TR, 500S",
"devices": [
{
"productType": "0x4952",
"productId": "0x3133",
"zwaveAllianceId": [2690, 3746]
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"paramInformation": [
{
"#": "3",
"label": "LED Light",
"description": "Invert LED light",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "LED on when load is off, LED off when load is on",
"value": 0
},
{
"label": "LED on when load is on, LED off when load is off",
"value": 1
},
{
"label": "LED always off",
"value": 2
}
]
}
],
"metadata": {
"inclusion": "Follow the instructions for your Z-Wave certified\ncontroller to add a device to the Z-Wave network.\n2. Once the controller is ready to add your device, press and\nrelease the Program Button to add it in the network",
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to\nremove a device from the Z-Wave network.\n2. Once the controller is ready to remove your device, press and\nrelease the manual/program button to remove it from the\nnetwork",
"reset": "Press the button 3 times, then press and hold the button for at least 3\nseconds. The LED will blink 5 times to confirm.\nNOTE: This should only be used in the event your networks primary\ncontroller is missing or otherwise inoperable",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2690/39349_HQSG_1.pdf"
}
}