zwave-js/.config-db/devices/0x5254/zts-110.json

165 lines
2.8 KiB
JSON
Raw Permalink Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Remotec",
"manufacturerId": "0x5254",
"label": "ZTS-110",
"description": "ZTS-110 Z Wave Thermostat",
"devices": [
{
"productType": "0x0200",
"productId": "0x8031",
"zwaveAllianceId": 679
},
{
"productType": "0x0202",
"productId": "0x8031"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Heat Pump",
"maxNodes": 4
},
"2": {
"label": "Compressor",
"maxNodes": 4
},
"3": {
"label": "Controller Update",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"label": "Swing",
"description": "Set Swing value from 1F/.5C to 4F/2.0C Available settings: 1 - 4",
"valueSize": 1,
"minValue": 1,
"maxValue": 4,
"defaultValue": 2
},
{
"#": "2",
"label": "Differential",
"description": "Set Differential value from 1F/.5C to 4F/2.0C Available settings: 1 - 4",
"valueSize": 1,
"minValue": 1,
"maxValue": 4,
"defaultValue": 2
},
{
"#": "3",
"label": "Set Filter Counter",
"valueSize": 2,
"unit": "hours",
"minValue": 500,
"maxValue": 4000,
"defaultValue": 500
},
{
"#": "4",
"label": "Report Filter Counter",
"valueSize": 2,
"unit": "hours",
"minValue": 0,
"maxValue": 9999,
"defaultValue": 0,
"readOnly": true
},
{
"#": "5",
"label": "Temperature Scale",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "Centigrade",
"value": 0
},
{
"label": "Fahrenheit",
"value": 1
}
]
},
{
"#": "6",
"label": "Upper Limit of Setpoint A",
"valueSize": 2,
"minValue": 37,
"maxValue": 99,
"defaultValue": 99
},
{
"#": "7",
"label": "Lower Limit of Setpoint B",
"valueSize": 2,
"minValue": 5,
"maxValue": 95,
"defaultValue": 41
},
{
"#": "8",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Easy Mode",
"defaultValue": 1
},
{
"#": "9",
"label": "Time Format",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "24 hour",
"value": 0
},
{
"label": "12 hour",
"value": 1
}
]
},
{
"#": "10",
"label": "Repeat Basic Set Counter",
"valueSize": 1,
"minValue": 0,
"maxValue": 255,
"defaultValue": 0,
"unsigned": true
},
{
"#": "11",
"label": "AUTO Report by Room Temperature",
"valueSize": 1,
"minValue": 0,
"maxValue": 8,
"defaultValue": 4
},
{
"#": "12",
"label": "Sensor Temperature Calibration",
"valueSize": 1,
"minValue": -10,
"maxValue": 10,
"defaultValue": 0
},
{
"#": "13",
"label": "AUTO Report by Time Interval",
"valueSize": 1,
"minValue": 0,
"maxValue": 16,
"defaultValue": 0
}
]
}