zwave-js/.config-db/devices/0x032e/dat-101.json

374 lines
6.5 KiB
JSON
Raw Permalink Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Defaro",
"manufacturerId": "0x032e",
"label": "DAT-101",
"description": "Thermostat Actuator",
"devices": [
{
"productType": "0x0013",
"productId": "0x0021"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "State Changes",
"maxNodes": 10,
"isLifeline": true
},
"2": {
"label": "External Temperature Sensor",
"maxNodes": 1
}
},
"paramInformation": [
{
"#": "1",
"label": "Relay NO/NC Mode",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Normal open",
"value": 0
},
{
"label": "Normal close",
"value": 1
}
]
},
{
"#": "2",
"label": "Hysteresis",
"valueSize": 1,
"unit": "°C",
"minValue": 1,
"maxValue": 7,
"defaultValue": 1
},
{
"#": "3",
"label": "Hysteresis Offset",
"valueSize": 1,
"defaultValue": 2,
"allowManualEntry": false,
"options": [
{
"label": "Turn on at setpoint, turn off at setpoint + hysteresis",
"value": 0
},
{
"label": "Turn on at setpoint - Hysteresis, turn off at setpoint",
"value": 1
},
{
"label": "Turn on at setpoint - ½ hysteresis, turn off at setpoint + ½ hysteresis",
"value": 2
}
]
},
{
"#": "4",
"label": "Default Relay Status",
"valueSize": 1,
"minValue": 0,
"maxValue": 1,
"defaultValue": 1,
"options": [
{
"label": "Relay off (Recommended for electric floor heating)",
"value": 0
},
{
"label": "Relay on",
"value": 1
}
]
},
{
"#": "6",
"label": "Minimum Temperature",
"valueSize": 2,
"unit": "°C",
"minValue": -127,
"maxValue": 127,
"defaultValue": 4
},
{
"#": "7",
"label": "Maximum Temperature",
"valueSize": 2,
"unit": "°C",
"minValue": -127,
"maxValue": 127,
"defaultValue": 30
},
{
"#": "8",
"label": "Turbo Mode: Duration",
"valueSize": 2,
"unit": "seconds",
"minValue": 100,
"maxValue": 1200,
"defaultValue": 120
},
{
"#": "9",
"label": "Turbo Mode: Consider Thermostat Mode",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Consider",
"value": 0
},
{
"label": "Do not consider",
"value": 1
}
]
},
{
"#": "10",
"label": "Thermostat Temperature Sensor Type",
"description": "When polling, the external sensor must be added to the 2nd association group. When listening, the DAT-101 must be added to the corresponding association group of the external sensor.",
"valueSize": 1,
"minValue": 0,
"maxValue": 2,
"defaultValue": 0,
"options": [
{
"label": "Stock temp sensor",
"value": 0
},
{
"label": "External temperature sensor (Polling)",
"value": 1
},
{
"label": "External temperature sensor (Listening)",
"value": 2
}
]
},
{
"#": "11",
"label": "External Temperature Sensor: Poll Interval",
"valueSize": 2,
"unit": "seconds",
"minValue": 10,
"maxValue": 600,
"defaultValue": 300
},
{
"#": "5",
"label": "External Temperature Sensor: Report Timeout",
"description": "After the specified timeout, lack of temperature reports from the external sensor will be considered a failure.",
"valueSize": 2,
"unit": "seconds",
"minValue": 100,
"maxValue": 30000,
"defaultValue": 30000
},
{
"#": "12",
"label": "Automatic Reports: Temperature Change Threshold",
"valueSize": 2,
"unit": "°C",
"minValue": 1,
"maxValue": 16,
"defaultValue": 1
},
{
"#": "13",
"label": "Automatic Reports: Interval",
"valueSize": 2,
"unit": "seconds",
"minValue": 10,
"maxValue": 600,
"defaultValue": 300
},
{
"#": "14",
"label": "Automatic Reports: After Changing Relay State",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Enable",
"value": 0
},
{
"label": "Disable",
"value": 1
}
]
},
{
"#": "15",
"label": "Switch 1 Mode (Thermostat Mode)",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Monostable",
"value": 0
},
{
"label": "Bistable, fixed position 1 (Contacts connected - On, disconnected - Off)",
"value": 1
},
{
"label": "Bistable, fixed position 2 (Contacts disconnected - On, connected - Off)",
"value": 2
},
{
"label": "Bistable (Every push will switch relay)",
"value": 3
}
]
},
{
"#": "16",
"label": "Switch 2 Mode (Turbo Mode)",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Monostable",
"value": 0
},
{
"label": "Bistable, fixed position 1 (Contacts connected - On, disconnected - Off)",
"value": 1
},
{
"label": "Bistable, fixed position 2 (Contacts disconnected - On, connected - Off)",
"value": 2
},
{
"label": "Bistable (Every push will switch relay)",
"value": 3
}
]
},
{
"#": "40",
"label": "Temperature Sensor 1: Calibration",
"valueSize": 2,
"unit": "°C",
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "+/- 0",
"value": 0
},
{
"label": "+1",
"value": 1
},
{
"label": "+2",
"value": 2
},
{
"label": "+3",
"value": 3
},
{
"label": "+4",
"value": 4
},
{
"label": "+5",
"value": 5
},
{
"label": "-1",
"value": 6
},
{
"label": "-2",
"value": 7
},
{
"label": "-3",
"value": 8
},
{
"label": "-4",
"value": 9
},
{
"label": "-5",
"value": 10
}
]
},
{
"#": "41",
"label": "Temperature Sensor 2: Calibration",
"valueSize": 2,
"unit": "°C",
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "+/- 0",
"value": 0
},
{
"label": "+1",
"value": 1
},
{
"label": "+2",
"value": 2
},
{
"label": "+3",
"value": 3
},
{
"label": "+4",
"value": 4
},
{
"label": "+5",
"value": 5
},
{
"label": "-1",
"value": 6
},
{
"label": "-2",
"value": 7
},
{
"label": "-3",
"value": 8
},
{
"label": "-4",
"value": 9
},
{
"label": "-5",
"value": 10
}
]
}
]
}