zwave-js/.config-db/devices/0x0208/hkzw-so08.json

185 lines
3.3 KiB
JSON
Raw Permalink Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Hank",
"manufacturerId": "0x0208",
"label": "HKZW-SO08",
"description": "Smart Plug",
"devices": [
{
"productType": "0x0100",
"productId": "0x0019"
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 5,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "20",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Overload Protection",
"description": "If current exceeds 11.5A over 5 seconds, relay will turn off.",
"defaultValue": 1
},
{
"#": "21",
"$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off"
},
{
"#": "24",
"label": "Send Basic Report on State Change",
"valueSize": 1,
"minValue": 0,
"maxValue": 2,
"defaultValue": 1,
"options": [
{
"label": "Disabled",
"value": 0
},
{
"label": "Enabled",
"value": 1
},
{
"label": "Only when controlled locally",
"value": 2
}
]
},
{
"#": "27",
"label": "Indicator Mode",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "LED on for 5 seconds, then off",
"value": 0
},
{
"label": "On when load is on",
"value": 1
}
]
},
{
"#": "151",
"label": "Power Change Report Threshold",
"valueSize": 2,
"unit": "W",
"minValue": 0,
"maxValue": 200,
"defaultValue": 50,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "152",
"$import": "~/templates/master_template.json#base_0-100_nounit",
"label": "Relative Power Change Report Threshold",
"unit": "%",
"defaultValue": 10,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "171",
"label": "Power (W) Report Interval",
"description": "Minimum value 3600, if not disabled",
"valueSize": 4,
"unit": "seconds",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 3600,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "172",
"label": "Energy (kWh) Report Interval",
"description": "Minimum value 3600, if not disabled",
"valueSize": 4,
"unit": "seconds",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 7200,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "173",
"label": "Voltage (V) Report Interval",
"description": "Minimum value 3600, if not disabled",
"valueSize": 4,
"unit": "seconds",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 0,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "174",
"label": "Current (A) Report Interval",
"description": "Minimum value 3600, if not disabled",
"valueSize": 4,
"unit": "seconds",
"minValue": 0,
"maxValue": 2678400,
"defaultValue": 0,
"options": [
{
"label": "Disabled",
"value": 0
}
]
},
{
"#": "254",
"label": "Lock Configuration",
"valueSize": 1,
"defaultValue": 0,
"allowManualEntry": false,
"options": [
{
"label": "Unlocked",
"value": 0
},
{
"label": "Locked",
"value": 1
}
]
}
]
}