zwave-js/.config-db/devices/0x015d/zen20.json

260 lines
7.5 KiB
JSON
Raw Permalink Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Zooz",
"manufacturerId": "0x015d",
"label": "ZEN20",
"description": "Smart Energy Power Strip",
"devices": [
{
"productType": "0x0621",
"productId": "0xf51c",
"zwaveAllianceId": 1818
},
{
"productType": "0x0651",
"productId": "0xf51c",
"zwaveAllianceId": 1646
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Lifeline",
"maxNodes": 1,
"isLifeline": true
}
},
"paramInformation": [
{
"#": "1",
"$import": "~/templates/master_template.json#state_after_power_failure_prev_on_off"
},
{
"#": "2",
"label": "Power Wattage Report Value Threshold",
"description": "Choose how you want your Power Strip to report power consumption to your hub",
"valueSize": 2,
"minValue": 0,
"maxValue": 65535,
"defaultValue": 5,
"unsigned": true
},
{
"#": "3",
"label": "Power Wattage Report Frequency",
"description": "The number entered as value corresponds to the number of seconds",
"valueSize": 4,
"unit": "seconds",
"minValue": 5,
"maxValue": 2678400,
"defaultValue": 30
},
{
"#": "4",
"label": "Energy (kWh) Report Frequency",
"description": "Report interval of power consumption (W) to your controller (hub)",
"valueSize": 4,
"unit": "seconds",
"minValue": 5,
"maxValue": 2678400,
"defaultValue": 300
},
{
"#": "5",
"label": "Overload Protection",
"description": "Set the Watt level for overload protection to kick in",
"valueSize": 2,
"minValue": 0,
"maxValue": 1500,
"defaultValue": 1500
},
{
"#": "6",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH1 Auto Turn-Off Timer"
},
{
"#": "7",
"label": "CH1 Auto Turn-Off Setting",
"description": "Time in minutes to turn off the device connected to CH1 after being turned on",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "8",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH1 Auto Turn-On Timer"
},
{
"#": "9",
"label": "CH1 Auto Turn-On Setting",
"description": "Time in minutes to turn on the device connected to CH1 after being turned off.",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "10",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH2 Auto Turn-Off Timer"
},
{
"#": "11",
"label": "CH2 Auto Turn-Off Setting",
"description": "Time in minutes to turn off the device connected to CH2 after being turned on",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "12",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH2 Auto Turn-On Timer"
},
{
"#": "13",
"label": "CH2 Auto Turn-On Setting",
"description": "Time in minutes to turn on the device connected to CH2 after being turned off",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "14",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH3 Auto Turn-Off Timer"
},
{
"#": "15",
"label": "CH3 Auto Turn-Off Setting",
"description": "Time in minutes to turn off the device connected to CH3 after being turned on",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "16",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH3 Auto Turn-On Timer"
},
{
"#": "17",
"label": "CH3 Auto Turn-On Setting",
"description": "Time in minutes to turn on the device connected to CH3 after being turned off",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "18",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH4 Auto Turn-Off Timer"
},
{
"#": "19",
"label": "CH4 Auto Turn-Off Setting",
"description": "Time in minutes to turn off the device connected to CH4 after being turned on.",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "20",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH4 Auto Turn-On Timer"
},
{
"#": "21",
"label": "CH4 Auto Turn-On Setting",
"description": "Time in minutes to turn on the device connected to CH4 after being turned off",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "22",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH5 Auto Turn-Off Timer"
},
{
"#": "23",
"label": "CH5 Auto Turn-Off Setting",
"description": "Time in minutes to turn off the device connected to CH5 after being turned on.",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "24",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "CH5 Auto Turn-On Timer"
},
{
"#": "25",
"label": "CH5 Auto Turn-On Setting",
"description": "Time in minutes to turn on the device connected to CH5 after being turned off",
"valueSize": 4,
"unit": "minutes",
"minValue": 1,
"maxValue": 65535,
"defaultValue": 60
},
{
"#": "26",
"$import": "~/templates/master_template.json#base_enable_disable",
"label": "Manual Control",
"description": "Enable / Disable Physical Button Functionality",
"defaultValue": 1
},
{
"#": "27",
"label": "LED Indicator Mode",
"description": "LED Outlet Indicator Behavior",
"valueSize": 1,
"defaultValue": 1,
"allowManualEntry": false,
"options": [
{
"label": "LED on when power is off and off when power is on",
"value": 0
},
{
"label": "LED on when power is on and off when power is off",
"value": 1
},
{
"label": "LED is always off, regardless of power status",
"value": 2
}
]
}
],
"metadata": {
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to include a device to \n the Z-Wave network.\n2. Once the controller is ready to include your device, press up and release the toggle \n to include it in the network.\n3. Once your controller has confirmed that the device has been included, refresh the \n Z-Wave network to optimize performance.\n4. The device is associated in the same group when it included in setting process. \n Now you can control your Z-Wave device according to groups, scenes, schedules and automation programmed",
"exclusion": "1. Plug the power strip into a grounded receptacle located within 3 feet from your Z-Wave gateway controller\n\n2. Put your Z-Wave controller in exclusion mode\n\n3. Press and release the power button on the strip\n\n4. The device should disappear from your controller's device list",
"reset": "When your networks primary controller is missing or otherwise inoperable, you may need to reset the device to factory settings manually. In order to complete the process, plug the power strip into a grounded receptacle, then PRESS AND HOLD the power button for AT LEAST 3 SECONDS. NOTE: All previously recorded activity and custom settings will be erased from the devices memory",
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/1818/Zooz-Z-Wave-Power-Strip-Zen20-Manual.pdf"
}
}