"manufacturer": "Ecolink",
|
|||
|
"manufacturerId": "0x014a",
|
|||
|
"label": "H214104",
|
|||
|
"description": "Z-Wave Wireless Flood/Freeze Sensor",
|
|||
|
"devices": [
|
|||
|
{
|
|||
|
"productType": "0x0005",
|
|||
|
"productId": "0x0010",
|
|||
|
"zwaveAllianceId": 2929
|
|||
|
}
|
|||
|
],
|
|||
|
"firmwareVersion": {
|
|||
|
"min": "0.0",
|
|||
|
"max": "255.255"
|
|||
|
},
|
|||
|
"metadata": {
|
|||
|
"inclusion": "The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network both the sensor and the network controller must be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controller’s inclusion mode. \n\n1) Verify that the Z-Wave Plus controller you are using is compatible with the Flood Freeze sensor.\n2) Either mount or move the Flood Freeze sensor as close as possible to the location the sensor will remain. See installation section below.\n3) Put your Z-Wave Plus Controller into add (inclusion) mode. \n4) To add the sensor to an existing Z-Wave network, follow the directions to put your Z-Wave Controller into add (inclusion) mode. The Flood Freeze enters add and remove (inclusion/exclusion) when powered on (when battery is added). If the LED starts blinking continuously, the sensor has no node ID and was not successfully added, so start step C over again. Make sure to remove the battery for 10 seconds if adding to a Z-Wave network fails. \n5) If after 5 seconds the LED is not blinking, look on the Z-Wave controller’s interface for feedback on whether the sensor was added successfully. If you do not see any feedback that the sensor was added, follow directions for removing the sensor from a Z-Wave network, and then try adding the sensor again. If you are still having problems, you may need to add additional Z-Wave listening devices in-between the controller and the sensor.",
|
|||
|
"exclusion": "1) Any sensor can be removed from any Z-Wave Plus controller. Follow the directions to put your Z-Wave Plus Controller into exclusion mode. Please use this procedure only when the network primary controller is missing or otherwise inoperable.\n2) Open the Flood Freeze case and remove the battery for 1 seconds. Replace the battery and the controller should remove the device from the Z-Wave network.",
|
|||
|
"reset": "The Flood Freeze sensor factory defaults on network exclusion. Please use this procedure only when the network primary controller is missing or otherwise inoperable.\" - You may use wording of your own choosing as long as it effectively means the same thing",
|
|||
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=MarketCertificationFiles/2929/51557%20%20Z-Wave%20FLF%20H214104%20ZWAVE_Ver04.pdf"
|
|||
|
}
|
|||
|
}
|