zwave-js/.config-db/devices/0x0060/st814.json

161 lines
3 KiB
JSON
Raw Permalink Normal View History

2025-01-10 22:05:04 -08:00
{
"manufacturer": "Everspring",
"manufacturerId": "0x0060",
"label": "ST814",
"description": "Temperature and Humidity Sensor",
"devices": [
{
"productType": "0x0006",
"productId": "0x0001",
"zwaveAllianceId": [271, 3, 923, 934, 974]
}
],
"firmwareVersion": {
"min": "0.0",
"max": "255.255"
},
"associations": {
"1": {
"label": "Reports",
"maxNodes": 1,
"isLifeline": true
},
"2": {
"label": "Control",
"maxNodes": 3
}
},
"paramInformation": [
{
"#": "1",
"label": "Dim Level Sent via Basic Set",
"valueSize": 1,
"minValue": 0,
"maxValue": 99,
"defaultValue": 99,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "2",
"label": "Temperature Trigger ON Value",
"description": "Temperature level when a ON command is sent out. Allowable range -20..50, 99.",
"valueSize": 1,
"unit": "°C/F",
"minValue": -20,
"maxValue": 99,
"defaultValue": 99,
"options": [
{
"label": "Disable",
"value": 99
}
]
},
{
"#": "3",
"label": "Temperature Trigger OFF Value",
"description": "Temperature level when a OFF command is sent out. Allowable range -20..50, 99.",
"valueSize": 1,
"unit": "°C/F",
"minValue": -20,
"maxValue": 99,
"defaultValue": 99,
"options": [
{
"label": "Disable",
"value": 99
}
]
},
{
"#": "4",
"label": "Humidity Trigger ON Value",
"description": "Humidity level when a ON command is sent out. Allowable range 20..90, 99.",
"valueSize": 1,
"unit": "%rH",
"minValue": 20,
"maxValue": 99,
"defaultValue": 99,
"options": [
{
"label": "Disable",
"value": 99
}
]
},
{
"#": "5",
"label": "Humidity Trigger OFF Value",
"description": "Humidity level when a OFF command is sent out. Allowable range 20..90, 99.",
"valueSize": 1,
"unit": "%rH",
"minValue": 20,
"maxValue": 99,
"defaultValue": 99,
"options": [
{
"label": "Disable",
"value": 99
}
]
},
{
"#": "6",
"label": "Auto Report Time",
"description": "Sets the time interval when a sensor report is sent",
"valueSize": 2,
"unit": "minutes",
"minValue": 0,
"maxValue": 1439,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "7",
"label": "Auto Report Temperature",
"description": "Sets the temperature change causing a sensor report.",
"valueSize": 1,
"unit": "°C/F",
"minValue": 0,
"maxValue": 70,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
},
{
"#": "8",
"label": "Auto Report Humidity",
"description": "Sets the humidity change causing a sensor report. Allowable range: 0, 5..70.",
"valueSize": 1,
"unit": "%rH",
"minValue": 0,
"maxValue": 70,
"defaultValue": 0,
"options": [
{
"label": "Disable",
"value": 0
}
]
}
],
"compat": {
// The device shouldn't have any endpoints, but it does say so
"removeEndpoints": "*"
}
}