102 lines
2.6 KiB
JSON
102 lines
2.6 KiB
JSON
|
{
|
||
|
"manufacturer": "Honeywell",
|
||
|
"manufacturerId": "0x0039",
|
||
|
"label": "39348 / 39455 / ZW4005",
|
||
|
"description": "In-Wall Paddle Switch, 500S",
|
||
|
"devices": [
|
||
|
{
|
||
|
"productType": "0x4952",
|
||
|
"productId": "0x3036",
|
||
|
"zwaveAllianceId": [2689, 3745]
|
||
|
}
|
||
|
],
|
||
|
"firmwareVersion": {
|
||
|
"min": "0.0",
|
||
|
"max": "255.255"
|
||
|
},
|
||
|
"associations": {
|
||
|
"1": {
|
||
|
"label": "Lifeline",
|
||
|
"maxNodes": 5,
|
||
|
"isLifeline": true
|
||
|
},
|
||
|
"2": {
|
||
|
"label": "Single Press",
|
||
|
"maxNodes": 5
|
||
|
},
|
||
|
"3": {
|
||
|
"label": "Double Tap",
|
||
|
"maxNodes": 5,
|
||
|
"isLifeline": true
|
||
|
}
|
||
|
},
|
||
|
"paramInformation": [
|
||
|
{
|
||
|
"#": "3",
|
||
|
"label": "LED Indicator",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 0,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "LED on when switch is off",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "LED on when switch is on",
|
||
|
"value": 1
|
||
|
},
|
||
|
{
|
||
|
"label": "LED always off",
|
||
|
"value": 2
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "4",
|
||
|
"label": "Invert Switch",
|
||
|
"valueSize": 1,
|
||
|
"minValue": 0,
|
||
|
"maxValue": 1,
|
||
|
"defaultValue": 0,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "No",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "Yes",
|
||
|
"value": 1
|
||
|
}
|
||
|
]
|
||
|
},
|
||
|
{
|
||
|
"#": "19",
|
||
|
"label": "Alternate Exclusion",
|
||
|
"valueSize": 1,
|
||
|
"defaultValue": 0,
|
||
|
"allowManualEntry": false,
|
||
|
"options": [
|
||
|
{
|
||
|
"label": "Press any button on the switch",
|
||
|
"value": 0
|
||
|
},
|
||
|
{
|
||
|
"label": "Press two times on button and two times off button",
|
||
|
"value": 1
|
||
|
}
|
||
|
]
|
||
|
}
|
||
|
],
|
||
|
"compat": {
|
||
|
"mapBasicReport": false,
|
||
|
"mapBasicSet": "event"
|
||
|
},
|
||
|
"metadata": {
|
||
|
"inclusion": "1. Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.\n2. Once the controller is ready to include your device, press and release the top or bottom of the wireless smart switch(rocker) to include it in the network.\n3. Once your controller has confirmed that the device has been included, refresh the Z-Wave network to optimize performance",
|
||
|
"exclusion": "1. Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network. \n2. Once the controller is ready to exclude your device, press and release the top button of the wireless smart switch (rocker) to exclude it from the network",
|
||
|
"reset": "Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times. The LED will flash ON/OFF 5 times when completed successfully. \nNote: Please use this reset procedure only when the primary controller is missing or inoperable.",
|
||
|
"manual": "https://products.z-wavealliance.org/ProductManual/File?folder=&filename=product_documents/3745/39455_HQSG_v3.pdf"
|
||
|
}
|
||
|
}
|